Document
- Electrical
- Foundation
- HVAC
- Home Inspection
- Pest
- Plumbing
- Roof
- Windows
On August 23, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 2463 Shannonaire Drive, Jennings, MO 63136.
- Record date
Available findings
- Electrical
Missing and non-functional smoke detectors need replacement with operational units; busted porch light at rear patio has exposed hot wires; ungrounded two-prong outlets are present throughout the home; exterior electric noted as needing repairs.
- HVAC
The Ruud furnace (manufactured 2016, 75,000 BTU) has had its heat exchanger removed and needs it replaced, rendering the HVAC inoperable; the HVAC exhaust duct has been torn loose; thermostat batteries need replacement; Ruud 2-ton condenser (2016) is present.
- Plumbing
Interior plumbing includes galvanized steel supply lines that need replacement; the water heater exhaust has lost its seal due to the furnace exhaust being ripped away; the 40-gallon Rheem water heater (manufactured 2018) shows signs of rust from previous moisture intrusion.
- Home Inspection
Whole-home inspection of a single-family property identified multiple deficiencies across roofing, structure, HVAC, plumbing, electrical, pest, and exterior systems requiring repair, replacement, or further evaluation before closing.
- Roof
Three-tab shingled roof estimated 20 years old is extensively patched with damaged/lifted shingles and needs full replacement; damaged soffit on front corner, tree limbs overhanging roof, and debris-filled/bent gutters also require attention.
- Foundation
One long horizontal crack is present on the north basement wall requiring repair; multiple cracks in the exterior foundation need epoxy injection sealing; signs of previous moisture intrusion with musty smell observed in basement; section of driveway concrete has sunk creating a trip hazard.
- Pest
Older termite damage is present on wood window shims, overhead garage door trim, and wood landscape timbers; full termite treatment for the home is recommended.
- Windows
One boarded-up window pane needs replacement and four missing or damaged window screens need to be replaced.