Record 1Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On August 23, 2023, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 2463 Shannonaire Drive, Jennings, MO 63136.

Record date

Available findings

  • Electrical

    Missing and non-functional smoke detectors need replacement with operational units; busted porch light at rear patio has exposed hot wires; ungrounded two-prong outlets are present throughout the home; exterior electric noted as needing repairs.

  • HVAC

    The Ruud furnace (manufactured 2016, 75,000 BTU) has had its heat exchanger removed and needs it replaced, rendering the HVAC inoperable; the HVAC exhaust duct has been torn loose; thermostat batteries need replacement; Ruud 2-ton condenser (2016) is present.

  • Plumbing

    Interior plumbing includes galvanized steel supply lines that need replacement; the water heater exhaust has lost its seal due to the furnace exhaust being ripped away; the 40-gallon Rheem water heater (manufactured 2018) shows signs of rust from previous moisture intrusion.

  • Home Inspection

    Whole-home inspection of a single-family property identified multiple deficiencies across roofing, structure, HVAC, plumbing, electrical, pest, and exterior systems requiring repair, replacement, or further evaluation before closing.

  • Roof

    Three-tab shingled roof estimated 20 years old is extensively patched with damaged/lifted shingles and needs full replacement; damaged soffit on front corner, tree limbs overhanging roof, and debris-filled/bent gutters also require attention.

  • Foundation

    One long horizontal crack is present on the north basement wall requiring repair; multiple cracks in the exterior foundation need epoxy injection sealing; signs of previous moisture intrusion with musty smell observed in basement; section of driveway concrete has sunk creating a trip hazard.

  • Pest

    Older termite damage is present on wood window shims, overhead garage door trim, and wood landscape timbers; full termite treatment for the home is recommended.

  • Windows

    One boarded-up window pane needs replacement and four missing or damaged window screens need to be replaced.

View 2463 Shannonaire Drive, Jennings, MO 63136 on Fresh House