HVAC Diagnostic and Leak Search — A/C nearly empty of refrigerant
- Foundation
- HVAC
- Plumbing
On August 27, 2026, Arch Air Services documented Foundation, HVAC, and Plumbing at 260 Sadonia Avenue, Ferguson, MO 63135.
- Record date
Available findings
- HVACCompleted work$497
Diagnostic service call found furnace service switch off (restored) and A/C unit almost completely empty of refrigerant with disconnect pullout loose inside condenser; performed electronic leak search after adding 1 lb R-410A, found no leaks — missing service port cap identified as likely cause; evaporator coil also noted to have no drain hose.
- HVACWork status not resolved
- PlumbingWork status not resolved
Photograph shows copper supply pipes running along a concrete block wall, with a brass fitting and a blue-handled shutoff valve visible in a basement or utility space.
- HVACWork status not resolved
Photograph shows the interior of an outdoor HVAC condenser unit with a capacitor, multi-colored wiring, and significant burn/char damage to wiring and electrical components in the center of the unit.
- FoundationWork status not resolved
Photograph shows an unfinished basement interior with a concrete floor exhibiting gray discoloration and patches, exposed ceiling joists with fiberglass insulation batts, black steel support columns, concrete block or painted walls, a white door in the background, a utility panel on the wall, and a hose or cord lying on the floor.