HVACCompleted work$349
Supplied an over 10 Mfd capacitor and performed seasonal heating maintenance, with a trip fee.
HVACWork status not resolved
Photograph shows the interior of an HVAC unit with a capacitor marked '12.5' (likely 12.5 μF) connected by two brown wires, an automatic ignition control board, a transformer, and a dense bundle of multi-colored control wiring.
HVACWork status not resolved
Photograph shows the interior of a gas furnace with access panel removed, revealing a run capacitor, control board, multiple wiring harnesses with wire nuts, a large black pipe/flue tube, burner ports, and visible rust/orange staining on the interior floor and heat exchanger area, indicating an aged unit with corrosion present.
HVACWork status not resolved
Photograph shows the open interior of a gas furnace, including a squirrel-cage blower motor with visible rust/corrosion on the housing, a gas valve with multi-color wiring harness, a blue multi-port burner assembly, and a control board with associated wiring.
HVACWork status not resolved
Photograph shows the interior of a gas furnace with the access panel removed, revealing multiple clamshell heat exchanger cells with visible orange rust/corrosion staining on the metal surfaces, a gas valve in the OFF position, multiple wiring harnesses, and a Carling Switch component at the bottom of the unit.
HVACWork status not resolved
Photograph shows a UEi PDT655 digital thermometer displaying 115°F placed on foil-taped HVAC ductwork, with black flexible duct visible in the background.
HVACWork status not resolved
Photograph shows a furnace interior with a heavily corroded/rusted cylindrical burner tube, a flame sensor or igniter rod with ceramic insulator, and aged push-on spade wire connectors (pink insulation with blue locking tab) on the galvanized sheet metal chassis.
HVACWork status not resolved
Photograph shows a gas furnace with access panels removed, exposing the inducer motor, heat exchanger, burner assembly, gas valve, control board, and wiring
HVACWork status not resolved
Photograph shows the interior of a gas furnace with the access panel removed, revealing a draft inducer blower motor assembly with visible rust and corrosion staining on the inducer scroll housing and surrounding metal surfaces, a gas valve with multi-colored wiring harness, and a control component shelf showing rust discoloration and mineral deposits.
HVACWork status not resolved
Photograph shows the interior of a gas furnace with three burner tubes actively firing; flames are predominantly blue but the center burner exhibits a visible orange/yellow spot, which may indicate incomplete combustion or a dirty burner.
HVACWork status not resolved