HVAC Seasonal Maintenance — Furnace unsafe: burnt wiring
- HVAC
On November 10, 2025, ASSURED HEATING AND COOLING documented HVAC at 2628 Avie Drive, Jennings, MO 63136.
- Record date
Available findings
- HVACCompleted work
Seasonal maintenance visit found burnt wiring and several roll out failure codes, typically from a cracked heat exchanger; system is not safe for operation and replacement is recommended.