Complete public upload archive

Property records for 268 Reasor Drive, Ferguson, MO 63135

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Repair — Replaced contactor and capacitor, washed coil

  • HVAC

On August 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 268 Reasor Drive, Ferguson, MO 63135.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$628

    Performed diagnostic, replaced contactor and capacitor, and washed condenser coil.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with its electrical access panel open; a cylindrical run capacitor and an old contactor have been removed and are resting on top of the unit, while a replacement contactor is visible installed inside the electrical compartment with multi-colored wiring connected.

  • HVACWork status not resolved

    Tenant reports central AC blowing warm air since 8/14/26; technician dispatched to diagnose and repair, with an estimate required if repairs exceed the maintenance limit.

  • HVACWork status not resolved

    Photograph shows a hook-shaped black metal line or conduit in the foreground near what appears to be condenser coil fins in the background, with a corroded/rusted pipe connection and red and black electrical wires visible below.

  • HVACWork status not resolved

    Fieldpiece refrigerant-side measurements on an R-22 system show suction pressure 87.4 psig, liquid pressure 295.4 psig, actual superheat 18.8°F, and actual subcooling 41.8°F.

  • HVACWork status not resolved

    Photograph shows Fieldpiece app refrigerant side measurements for an R-22 system: suction pressure 66.7 psig, discharge/liquid pressure 233.2 psig, vapor saturation 38.6°F, liquid saturation 112.1°F, actual superheat 32.0°F, actual subcooling 34.0°F, and liquid line temperature 78.1°F; suction temperature probe reads open.

  • HVACWork status not resolved

    Photograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily coated with dirt, dust, and debris, with a curved refrigerant line visible along the coil face.

  • HVACWork status not resolved

    Photograph shows a heavily soiled HVAC panel air filter with dark brown/black particulate accumulation covering the entire pleated filter media surface, indicating the filter is well past its service life and requires immediate replacement.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a heavily soiled, pleated HVAC air filter with cardboard frame that is completely blackened with accumulated dust and debris, indicating the filter is well past its service life and requires immediate replacement.

Record 2Public property record

HVAC Replacement Estimate — 2.5-ton 13 SEER Ameristar A/C and coil

  • HVAC

On August 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 268 Reasor Drive, Ferguson, MO 63135.

Record date

Available findings

  • HVACEstimate or proposed work$668

    Estimate for two options: immediate repairs (R-22 refrigerant, metering device, labor) and a 2.5-ton 13 SEER Ameristar air conditioner and evaporator coil replacement with condenser pad and 30-amp disconnect; both options expired.