HVAC Air Conditioner Install — Lennox Elite 16 SEER A/C install
- HVAC
On May 19, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 2804 Woodbridge Estates Drive, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$5,486
Installed new Lennox Elite 16 SEER air conditioner and evaporator with custom plenum to adapt to existing ductwork, evacuated line set, charged system with correct refrigerant, and performed start up testing.