HVAC Maintenance Invoice — AC/furnace maintenance performed
- HVAC
On October 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2930 Point Drive, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$145
Technician performed AC/furnace maintenance.
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter (dial set to OFF) positioned in front of a yellow EnergyGuide label on a natural gas furnace, with tools visible on the floor nearby.
- HVACWork status not resolved
Photograph shows a Fasco brand inducer motor (model J238-150) mounted inside an HVAC furnace cabinet, rated 115V, 60Hz, 2.63FLA, 3000RPM, with visible wiring harness and orange wires below.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements for R-410A system: suction pressure 112.8 psig, suction temperature 49.3°F, vapor saturation 37.5°F, actual superheat 11.8°F; liquid pressure 206.0 psig, liquid temperature 66.4°F, liquid saturation 71.3°F, actual subcooling 4.9°F, discharge pressure 112.8 psig.
- HVACWork status not resolved
Fieldpiece app shows live R-410A refrigerant readings: suction pressure 112.6 psig, liquid pressure 205.4 psig, actual superheat 12.0°F, actual subcooling 3.8°F.
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter with its LCD display reading 2.0 A in AC amperage mode.