HVAC Maintenance Service — A/C maintenance with R-32 refrigerant added
- HVAC
On May 20, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3 Trade Winds Drive, St. Peters, MO 63376.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$188
Performed air conditioning maintenance and supplied additional R-32 refrigerant per pound.
- HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant measurement screen for R-32 system: suction pressure 135.1 psig, liquid pressure 282.0 psig, actual superheat 16.2°F, and actual subcooling 1.8°F.
- HVACWork status not resolved
Photograph shows Fieldpiece app refrigerant measurement screen displaying R-32 refrigerant with suction pressure 126.7 psig, liquid pressure 249.6 psig, actual superheat 17.4°F, and actual subcooling 6.8°F.
- HVACWork status not resolved
ground around the unit is wet and muddy
- HVACWork status not resolved
Photograph shows multiple electrical wire splices joined with blue wire nuts in an open framing cavity, with no enclosing junction box visible; several cables of varying colors (white, red, yellow, green, blue) are loosely bundled and unsecured.
- HVACWork status not resolved
Maintenance meld opened for AC malfunction
- HVACWork status not resolved