Record 1Public property recordA

HVAC Condensate Drain Service — Clogged furnace condensate drain

  • HVAC

On August 13, 2026, ASSURED HEATING AND COOLING documented HVAC at 3001 South Compton Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$319

    Furnace leaking water onto basement floor; found the condensate drain clogged, removed the hose and purged the lines to clear the drain, and noted the floor drain has lots of dryer lint and debris.

Record 2Public property record

HVAC Seasonal Maintenance — Flame sensor cleaned; system not fired up

  • HVAC

On November 25, 2025, ASSURED HEATING AND COOLING documented HVAC at 3001 South Compton Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Seasonal maintenance visit: system in good condition, filter in good condition on arrival, flame sensor cleaned; system could not be fired up because thermostat access was unavailable.

  • HVACWork status not resolved

    Photograph shows a squirrel-cage blower wheel with heavy dust and debris accumulation coating the blades and surrounding scroll housing, indicating a significant maintenance deficiency.

  • HVACWork status not resolved

    Photograph shows an HVAC blower motor mounted within a squirrel cage blower wheel assembly; blower wheel fins exhibit heavy dust and debris accumulation; a motor data plate with electrical specifications (single-phase, RPM, Hz) is visible on the motor body.

  • HVACWork status not resolved

    Photograph shows the interior of an open furnace with visible wiring harnesses, a gas valve component with a partially legible label, a black condensate/drain pan, and a control circuit board in the lower compartment.

  • HVACWork status not resolved

    Photograph shows the interior of a furnace with the access panel open, revealing a control circuit board with multiple wiring harnesses, a white ceramic L-shaped igniter component being held by a hand, a transformer, relays, and a yellow warning label on the unit cabinet; a Magic Filter box is visible nearby.

  • HVACWork status not resolved
Record 3Public property record

HVAC Seasonal Maintenance — Non-code gas flex line union in furnace

  • HVAC

On November 25, 2025, ASSURED HEATING AND COOLING documented HVAC at 3001 South Compton Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Seasonal maintenance performed on furnace: replaced and cleaned the filter; found flex gas line with a union inside the furnace cabinet that is not code compliant, and blower motor blades with dirt buildup that should be cleaned soon.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with a yellow CSST gas supply line connected to a gas valve assembly, multiple control wires, and visible rust/corrosion staining along the heat exchanger drum seam with dust and debris accumulation on the base pan.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with access panel removed, revealing the inducer/draft blower motor assembly, gas valve, burner/heat exchanger tubes, associated wiring, and a filter slot at the bottom with a red indicator strip.

  • HVACWork status not resolved

    Photograph shows a worn Goodman factory test report label inside an HVAC unit cabinet; System Test Result reads PASS with individual sub-tests (Hipot, Cool Blower, Vent Motor, Igniter, Leak, Heat Blower, Block Off) all showing PASS or enabled status.

  • HVACWork status not resolved

    Photograph shows a squirrel-cage blower wheel with heavy dust and debris accumulation on the blades, a piece of crumpled foil/debris lodged between the blades, and a barcode label (B1368034) visible on the center hub.

  • HVACWork status not resolved

    Photograph shows an HVAC blower (squirrel cage) wheel with heavy accumulation of dust and debris packed between the blades on both sides and the lower wheel assembly, indicating the unit is significantly overdue for cleaning.

Record 4Public property record

HVAC Repair — Gas line redone to code, pressure switch replaced

  • HVAC

On January 9, 2026, ASSURED HEATING AND COOLING documented HVAC at 3001 South Compton Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$790

    Re-did gas line to code, cleaned blower and wheel, and replaced faulty pressure switch.

  • HVACWork status not resolved

    Photograph shows a gas furnace in a basement with its front access panel removed, exposing the blower motor assembly, heat exchanger burner section, control board, and wiring; a yellow corrugated stainless steel (CSST) flexible gas supply line with a 'GAS' warning tag connects to the unit.

  • HVACWork status not resolved

    Photograph shows a gas furnace in a basement/crawlspace with the front access panel removed, exposing the inducer/draft blower assembly, heat exchanger, burner assembly, and associated wiring; a yellow flexible gas line and a water heater are visible in the background.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with access panel removed, revealing the draft inducer blower motor, pressure switch with yellow and white tubing, gas valve with blue fitting and wiring, and sheet metal ductwork above; white residue or staining is visible on the flue pipe/ductwork.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing active blue and orange flames burning across multiple burner ports, along with visible wiring, a gas valve or control component, and an inducer/draft motor assembly above the burner deck.

  • HVACWork status not resolved