- HVAC · Air conditioner contactor replaced to restore power control · Jun 2026
- HVAC · HVAC service trip performed at the property · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3070 Piney Pointe Drive, St. Louis, MO 63129. The amount summary includes $439 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Trip fee service visit
- HVAC
Built from Housecall Pro data
- $89HVACWork performed: Trip Fee.
- HVACPhotograph shows live R410A refrigerant readings via Testo 557s: vapor pressure 122.4 psi (saturation temp 41.8°F), liquid pressure 317.5 psi (saturation temp 99.8°F), suction line temp 32.0°F, liquid line temp 87.8°F, superheat reading invalid (XXX), and subcooling 12.0°F.
- HVACPhotograph shows a red digital thermometer being held in front of a louvered HVAC supply or return air register mounted on a wall, with a partially visible LCD temperature reading.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Contactor Replacement — Air conditioner contactor replaced
- HVAC
Built from Housecall Pro data
- $350HVACReplaced the air conditioner contactor, the component that controls power to the system.
- HVACPhotograph shows an electrical enclosure interior with a heavily corroded contactor/relay; rust and oxidation visible on copper bus bars and terminal lugs; along with multiple disorganized wires (yellow, black, brown, blue) and accumulated dust and debris throughout.