HVAC Diagnostic Service — , 2.5 hours labor
- HVAC
On August 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3117 RUSSELL, St. Louis, MO 63104.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$427
Performed a residential diagnostic service and 2.5 hours of residential labor at the service address.
- HVACWork status not resolved
Photograph shows the base of an HVAC air handler with a deteriorated condensate drain pipe connection, aged and dirty drain line, a float/safety switch, exposed wiring, and orange-brown staining on the wooden subfloor beneath the unit.
- HVACWork status not resolved
Photograph shows the underside of an air handler unit with white PVC condensate drain piping including elbow fittings, a vertical standpipe, flexible black insulated lines, and exposed electrical wiring (red and orange) in the vicinity of a metal drip pan.
- HVACWork status not resolved
Photograph shows a ceiling-mounted HVAC vent grille with heavy accumulation of dark dust, lint, and fibrous debris coating the slats and surrounding frame.
- HVACWork status not resolved
Photograph shows a white louvered HVAC vent register with heavy accumulation of dust, lint, and fibrous debris on and between the slats, indicating the register has not been cleaned in an extended period.
- HVACWork status not resolved
Photograph shows an unfinished basement ceiling with multiple exposed electrical wires and cables (including colored conductors) running between wood joists, a large conduit routed along the wall-ceiling junction, and white J-hooks supporting cables from the joists.
- HVACWork status not resolved
Photograph shows a condensate pump (white motor unit on black reservoir) sitting in blown-in insulation in an attic space, with flexible tubing, a white PVC discharge pipe, and multiple loose electrical wires (black, orange, blue) running through the insulation nearby.
- HVACWork status not resolved
Photograph shows a light-colored surface scattered with numerous dark specks and debris consistent with pest droppings or frass, with metal tweezers pointing at the surface and crinkled metallic material visible in the upper corner.
- HVACWork status not resolved
Photograph shows a PVC tee fitting with a red plug inserted into the upward-facing port, located near mechanical equipment in what appears to be a utility room.
- HVACWork status not resolved
Photograph shows several white PVC pipes bundled together with a black rubber strip, stored on a worn wood floor in what appears to be a storage or basement space; a coiled blue hose or cable is also visible nearby.
- HVACWork status not resolved
Photograph shows white PVC pipes with fittings and a braided flexible hose connected at the base of a deteriorated wooden post, with visible wet staining on the concrete floor nearby; old cast iron pipe stubs and a large gate valve in the brick wall are also visible.
- HVACWork status not resolved
Photograph shows a large-diameter metal pipe (likely cast iron) with severe corrosion, heavy rust, deep cracking, and chalky mineral deposits visible on the pipe face and exterior, suspended in what appears to be a crawl space or basement.
- HVACWork status not resolved
Photograph shows a visibly soiled air filter (approximately x22x1 inches) installed in an HVAC unit filter slot; the pre-printed 'DATE INSTALLED:' field on the filter frame is blank with no written date.
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a dark pipe with severely deteriorated and torn insulation or wrapping material, a copper line running across the frame, and a metal housing with visible bolts, located in what appears to be a crawl space or basement area.
- HVACWork status not resolved
Photograph shows a deteriorated underground pipe with its open end heavily obstructed by gray/tan buildup or scale, surrounded by corroded metal framing, wet soil, and debris.
- HVACWork status not resolved
Photograph shows a hand-held combustible gas leak detector (yellow) being used to probe exterior gas pipe fittings and connections at the base of a building wall amid ground cover vegetation.
- HVACWork status not resolved
Photograph shows the interior panel of an HVAC unit (furnace/air handler) with a manufacturer data plate/specification label, color-coded wiring connectors, and a control component mounted on the unit.