HVAC Service Call — Blower motor tripping breaker; wrong motor
- HVAC
On October 14, 2025, ASSURED HEATING AND COOLING documented HVAC at 3158 Oregon Avenue, St. Louis, MO 63118.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$89
Service call found the blower motor tripping the breaker; the factory ECM motor and control board had been replaced with mismatched parts, safeties are not correctly mounted, and the 10-year-old furnace shows several rigged repairs.
- HVACWork status not resolved
Photograph shows two HVAC blower motors on a concrete floor — one new motor with a multi-pin wiring harness connector and shaft (with packaging box nearby) and one older, used motor with ventilation slots and loose wiring, consistent with an in-progress motor replacement.
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit with heavily corroded and rusted sheet-metal panels, multiple wiring runs (red, yellow, purple, and white/brown wires), and what appear to be limit switches or thermal cutoff components mounted to the deteriorated metal surfaces; significant debris and dust accumulation is also visible.
- HVACWork status not resolved
Photograph shows a metal furnace heat exchanger panel with yellowish discoloration near the top edge and a visible diagonal seam or crack across the panel surface; cylindrical burner tubes are visible below.
- HVACWork status not resolved
Photograph shows the interior base pan of an HVAC cabinet with heavy rust/corrosion, reddish-brown sediment deposits, gray staining, and scattered debris on the floor of the unit.
- HVACWork status not resolved
Photograph shows heavy rust and corrosion on the sheet metal housing of an HVAC unit, with a deteriorated wiring harness connector and multiple wires (black, orange, red) exhibiting corrosion at the connection point.
- HVACWork status not resolved
Photograph shows the interior of a sheet metal HVAC air handler or plenum cabinet with heavy dust and debris accumulation on interior walls and floor surfaces; a copper pipe is visible at the lower left.