HVAC Diagnostic and Refrigerant Service — Diagnostic and 410-A
- HVAC
On June 12, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 316 Marilyn Drive, Arnold, MO 63010.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$425
Performed an overtime diagnostic for a club member and added 410-A refrigerant (3 lb max).
- HVACWork status not resolved
Fieldpiece refrigerant diagnostic shows R-410A system with suction pressure 116.9 psig, liquid pressure 299.1 psig, actual superheat 28.2°F, and actual subcooling 1.4°F; air side diagnostics indicate adequate airflow across the evaporator coil.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements show R-410A system with suction pressure 127.1 psig, liquid pressure 342.4 psig, actual superheat 18.8°F, actual subcooling 10.4°F, and air side dry bulb 50.4°F.
- HVACWork status not resolved
Photograph shows a Fieldpiece app screenshot of live HVAC air-side and refrigerant-side measurements: return dry bulb 70.3°F, supply dry bulb 50.4°F, Delta T 19.9°F, return RH 53.4%, supply RH 92.5%, suction pressure 127.1 psig, liquid pressure 342.2 psig.