← MAP

3706 MERAMEC

St. Louis, MO 6311638.5817°N, 90.2465°W
9Events
Contributed by:2 contributors
$39kDocumented amounts
SOURCE-BACKED RECORDS

Across 9 records on this home

Completed work

Invoices and paid receipts

$39k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

$339

Permitted value

$2.2k

Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 9 documented records

Fresh House Property Summary

Highlights selected from 9 documented records for this property.

  • HVAC
    HVAC · Three control boards replaced after overheating from dirty filters · Jan 2025
  • HVAC
    HVAC · Miswired air handler connections to breaker box found; electrician repair advised · Jan 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 3706 MERAMEC. I only speak from this property's source-backed records — 9 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

9 documented events
Contributed by: 2 contributors
First documented event: Jan 2020
Latest documented event: Jan 2026
First added to Fresh House: Oct 2026

1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.

Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 9 documented records for 3706 MERAMEC, St. Louis, MO 63116, dated from January 2020 through January 2026. The amount summary includes $39,014.98 in completed work across HVAC, $339 in estimates; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Plan Meeting — Plan install meeting, no charge

Document dated Jan 5, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Move — Furnace moved

Document dated Feb 6, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACMoved the furnace at the service address.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Outdoor Unit Installation — Last two outdoor units installed

Document dated Jun 3, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACInstalled the last two outdoor units, first AM.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Ductwork — 4 new HVAC systems with new ductwork

Document dated Jul 1, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $38,926
  • HVACInstalled new Rheem 2.5 ton condensing units, 95% AFUE furnaces and cased coils on the main level, 2.5 ton wall mount air handler systems on the second floor, all new ductwork, bathroom exhaust vents, theft deterrent cages, and additional line set.
    $38,926
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 1, 2024HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Control Board Repair — Control boards replaced in three units

Document dated Jan 21, 2025Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $339
  • HVACNormal hours service call; found three units not heating and replaced the control boards in each unit, which went out from overheating due to a dirty filter.
    $339

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Indoor blower not running; control board needed

Document dated Jun 26, 2025Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $89
  • HVACNormal hours service call: outdoor unit was functioning as intended, indoor unit blower motor was not turning on, and the control board needs replacement; the board was ordered.
    $89

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Invoice — Warranty board installed

Document dated Jul 8, 2025Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACInstalled warranty board.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Air handler 1w/2w wires mixed up at breaker box

Document dated Jan 15, 2026Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 3706 MERAMEC, St. Louis, MO 63116.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACUpon arrival found electricians mixed up 1w and 2w wires from air handler to breaker box, with not enough slack to move 1w into the correct panel; advised customer to have an electrician add a junction box to extend the wire and switch wires in the panel boxes.

Only original contributor can modify this entry

Create an account to manage your contributions over time

PERMIT

AP Permit AP-2020-170864

Permit issued Jan 14, 2020
Public recordPlumbingIssued

On January 14, 2020, City of St. Louis documented Plumbing at 3706 MERAMEC, St. Louis, MO 63116.

Applied
Jan 14, 2020
Permit #
AP-2020-170864
Declared valuation
$2,200

Declared on the permit, not confirmed spending or proof of completed work.

Contractor of record: ERVIN'S CONSTRUCTION LLC
City of St. Louis · source data last pulled Sep 30, 2026 · city publishes records by address

Obtained from a public records source; may contain reporting delays or errors.

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Plumbing
✓ documented
HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history