HVAC Service Call — Burner 4 not igniting; gas channels cleaned
- HVAC
On February 15, 2021, ASSURED HEATING AND COOLING documented HVAC at 3722 Melba Place, St. Louis, MO 63121.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$149
Service call found burner 4 (with the flame proving system) not igniting; removed the burner assembly and cleaned gas channels, and the system was working as intended; replacing the burner assembly, surface igniter and flame sensor was recommended.