HVACCompleted work$194
AC maintenance performed: cleaned outdoor coil, inspected system, replaced 16x25x1 system filter, and supplied a 2-pole 208-230 contactor with 24 volt control; contactor shows wear and replacement recommended; water heater inspected and turned up from low to hot setting.
HVACWork status not resolved
Photograph shows the open wiring compartment of an outdoor HVAC condenser unit with a motor run capacitor (330μF, 370V, Partners Best Choice model 01-0082, serial SA9398), a contactor with multiple wire connections, and heavy accumulation of dirt, dust, and cobwebs throughout the compartment.
HVACWork status not resolved
Photograph shows the interior electrical compartment of an HVAC condensing unit with a Mars 780 Definite Purpose Contactor (model 61755, 24VAC coil) and a motor run capacitor, with heavy accumulation of dirt, debris, and organic matter on the base and around components.
HVACWork status not resolved
Photograph shows the interior of an outdoor air conditioning condenser unit with an open access panel, revealing a Mars 780 General Purpose Contactor (model 617-series, rated 240/480/600 VAC, 40 FLA) with multiple colored wires connected; dirt and debris are visible on the unit base.
HVACWork status not resolved
Photograph shows a multi-pole contactor with labeled terminals (21, 23) and multiple colored wires (purple, yellow, blue, tan), with heavy accumulation of dust, lint, and cobwebs throughout the component and surrounding enclosure.