- HVAC · Gas furnace replaced with new Sure Comfort unit · Jan 2021
- HVAC · New gas shutoff, gas pipe, electrical switch, and flue work installed · Jan 2021
- HVAC · Prior furnace found failed; carbon monoxide detected in vents · Jan 2021
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3820 Greengrass Drive, Florissant, MO 63033, dated in January 2021. The amount summary includes $3,403.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Furnace Service Call — CO in vents; cracked heat exchanger
- HVAC
Built from Housecall Pro data
- $179HVACFurnace found not working; reset furnace, cleaned flame sensor, noted clogged filter, and a carbon monoxide test found carbon monoxide in the vents, indicating a cracked heat exchanger and that the furnace should be replaced.
- HVACPhotograph shows a heavily soiled pleated HVAC air filter with dark brown/gray dust, debris, and hair fibers covering the entire filter media surface, indicating the filter is well past its service life and in need of replacement.
- HVACvisible moisture or condensate residue is present on and around the burner assembly area
- UnclassifiedPhotograph shows a handheld carbon monoxide meter displaying a current reading of 025 ppm with a recorded maximum of 146 ppm, indicating a potentially hazardous CO level was detected.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Installation — Rheem 80% gas furnace installed
- HVAC
Built from Housecall Pro data
- $3,225HVACInstalled a Sure Comfort by Rheem Value Series 80% gas furnace (SA801CA100521MSA), including sheet metal adaptation, new gas shut off and gas pipe, new electrical switch and power, and flue work to existing lines.
- HVACPhotograph shows a gray upflow gas furnace with a single-wall metal flue vent pipe exiting the top, a blue service sticker on the upper cabinet door, and a data plate on the lower door; a small electronic control module is mounted to the right side of the unit.
- HVACPhotograph shows a large upflow air handler/furnace unit with sheet metal supply plenum and overhead ductwork in a basement mechanical area.
- HVACPhotograph shows a dark-colored furnace or air handler unit with an exposed coil section at the top, alongside a large sheet metal plenum/duct assembly, located in an unfinished basement mechanical area with concrete floor and exposed wood framing.
- HVACPhotograph shows a sheet metal air handler unit with an open or partially removed access panel, exposing internal coil/blower components; a yellow warning label is visible inside the unit; sheet metal duct transitions are present at the base.
- HVACa separate accessory unit (likely a humidifier or media filter cabinet) is visible to the right of the furnace
- HVAC · document contextPhotograph shows the front exterior of a single-story ranch-style home (address 3820) with a mixed stucco and red brick facade, dark asphalt shingle roof, covered front porch with dark painted columns and arched openings, multiple double-hung windows with black shutters, gutters along the roofline, and mulched landscaping beds with evergreen shrubs.
Documented warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- Labor
· source
“We do offer a 5 year Labor warranty for an additional $500”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
- labor
· source
“We offer a one year labor warranty at no additional cost.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.