Record 1Public property record

HVAC Service Invoice — HVAC service call, work not detailed

  • HVAC

On June 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3823 MICHIGAN, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$245

    the invoice does not describe the specific work performed

  • HVACWork status not resolved

    Photograph shows an outdoor condenser unit with heavily fouled, dirt-clogged condenser coils and visible physical damage/bending to the aluminum fins on the front face of the unit; the unit sits on a concrete pad next to a brick wall.

  • HVACWork status not resolved

    Photograph shows the exterior condenser coil fins of an outdoor AC unit heavily clogged with dirt and debris, significantly restricting airflow through the coil; the unit sits on a concrete pad with a wire protective grille in place.

  • HVACWork status not resolved

    Photograph shows heavily soiled and deteriorated duct insulation with a visible gap or separation at a duct joint, exposing the inner metallic duct surface; torn foil-faced insulation wrap is also visible.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with severely fouled and darkened condenser fins visible through the wire coil guard, indicating heavy debris accumulation and significant fin deterioration; unit sits on a concrete pad.

  • HVACWork status not resolved

    Photograph shows a furnace or air handler housing with visible orange-brown rust staining streaks running down the sheet metal panels, corrosion around screw holes, and a manufacturer's label identifying the component as a 'Housing' with part number NJK83243143.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit on a concrete pad with severely fouled, blackened, and matted condenser coil fins, indicating heavy dirt and debris accumulation restricting airflow.

  • HVACWork status not resolved

    Photograph shows a yellow SPK2 digital thermometer displaying a reading of 76.3° being held against a galvanized metal surface consistent with HVAC ductwork.

  • HVACWork status not resolved

    Photograph shows the exterior condenser coil fins of an outdoor HVAC unit heavily clogged with dirt and debris, appearing nearly black with significant buildup across the entire visible coil surface; a wire guard is mounted in front of the coil and the unit sits on a concrete pad.

  • HVACWork status not resolved

    Photograph shows an aged HVAC furnace control board (part no. 2821M044498, board no. 1162-202) mounted inside an equipment cabinet, with multiple multi-colored wiring harnesses connected; board surface shows dust accumulation and general wear.

  • HVACWork status not resolved

    Photograph shows a CSC dual run capacitor (35+5μF, 440VAC) mounted inside an HVAC unit cabinet, with yellow, red, and blue wiring connections visible; capacitor label indicates manufacture date of July 11, 2019.

  • HVACWork status not resolved

    Photograph shows the screen of a pipe inspection camera displaying the interior of a corrugated pipe with a visible joint offset or displacement and debris accumulation at the connection point.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with heavily fouled coil fins coated in a thick layer of dirt and debris, with a wire guard and refrigerant lines visible; the unit sits on a concrete pad.

  • HVACWork status not resolved

    Photograph shows a metal pipe penetrating a masonry wall with visible corrosion, rust-colored mineral staining, and an open or cracked joint seam at the pipe-wall interface.

  • HVACWork status not resolved

    Photograph shows a handheld SPK2 thermometer reading 124.5°F being held near galvanized metal HVAC ductwork.

  • HVACWork status not resolved

    Photograph shows a True RMS SC640 multimeter in temperature mode (TYPE K thermocouple) displaying a reading of 749, being used at an HVAC furnace or air handler unit; a carbon monoxide warning label is visible on the unit in the background.

  • HVACWork status not resolved

    surrounding area shows debris and foil-faced insulation

  • HVACWork status not resolved

    Photograph shows a Fieldpiece SC640 True RMS clamp meter displaying 8.44 A (AC) and 0.1 V, being used near what appears to be outdoor HVAC equipment.

  • UnclassifiedWork status not resolved

    Photograph shows a smartphone screen displaying the iOS Calculator app with the calculation 1,326 ÷ 281 = 4.71886121; no property document or system content is visible.

  • HVACWork status not resolved

    Photograph shows a Lennox outdoor condenser unit, model HS18-261-8P, using R-22 refrigerant (factory charge 2 lbs. 10 oz.), serial number 5188C17362, manufactured March 1988, with a DeWalt drill resting on top suggesting active service work.

  • HVACWork status not resolved

    Photograph shows a blower motor interior with heavy accumulation of dust and lint on the motor housing, wiring harness connector, and surrounding sheet metal surfaces; multiple colored wires (yellow, orange, blue, white, green, black) are visible at the motor connector.

  • HVACWork status not resolved

    Photograph shows a True RMS SC640 clamp multimeter displaying 1.12A and 0.2V AC, being used near a bundle of wires and a concrete wall with metal conduit.

  • HVACWork status not resolved

    Photograph shows interior of an open HVAC air handler with foil-faced insulation lining, visible rust and corrosion staining on the base/drain pan, and a technician using a DeWalt cordless drill to service the unit; pipes with a red shutoff valve are visible to the left.

  • HVACWork status not resolved

    Photograph shows an equipment identification label on an HVAC unit displaying Model Number TG8S080B12MP11B and Serial Number W1L4189824.

  • HVACWork status not resolved

    electrical wiring is visible in the lower right corner

  • HVACWork status not resolved

    Photograph shows a borescope/pipe inspection camera screen displaying the interior of a pipe with heavy rust, corrosion, and reddish-brown discoloration visible along the pipe walls.

  • UnclassifiedWork status not resolved

    Photograph shows an iPhone calculator app screen displaying the calculation 13,339.56 ÷ 359.5 with a result of 37.105869263; no property document or inspection content is present.

Record 2Official permit record

AE Permit AE-2025-267311

  • Electrical

On June 4, 2025, City of St. Louis documented Electrical at 3823 MICHIGAN, St. Louis, MO 63118.

Permit number
AE-2025-267311
Source status
Issued
Record date
Declared valuation
$4,000Declared on the permit, not confirmed spending or proof of completed work.
Official source
City of St. LouisSource data last pulled Sep 30, 2026

Available findings

  • ElectricalEstimate or proposed work$4,000

View the City of St. Louis property-level source