Complete public upload archive

Property records for 3828 South Lindbergh Boulevard, St. Louis, MO 63127

All 7 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 7.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Heating Maintenance — Seasonal heating maintenance

  • HVAC

On March 4, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$180

    Performed seasonal heating maintenance and supplied two 20/25/1 Merv 11 filters.

Record 2Public property record

HVAC Emergency Service Call — Emergency overtime commercial service

  • HVAC

On June 23, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$465

    Emergency overtime commercial service call with 1.5 hours of commercial overtime labor performed.

Record 3Public property record

HVAC Heating Maintenance — Seasonal heating maintenance

  • HVAC

On December 10, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$180

    Performed seasonal heating maintenance.

Record 4Public property record

HVAC Maintenance Invoice — RTU AC maintenance performed

  • HVAC

On April 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$180

    Performed rooftop unit (RTU) AC maintenance under the commercial maintenance plan (2 visits/year).

  • HVACWork status not resolved

    model 48FEEA04A2A3A0A0A0, serial 0225C08569, refrigerant R-454B, cooling capacity 34,000 BTU/h, SEER2 13.4, gas input max 90,000 BTU, output 73,500 BTU, thermal efficiency 81.2%, natural gas, AHRI Certified

  • HVACWork status not resolved

    Photograph shows a Testo digital refrigerant manifold gauge set displaying refrigeration system readings: low-side pressure 96.3 psi, high-side pressure 216.2 psi, evaporator temperature 34.7°F, and a probe temperature (T1/B45) of 34.3°F; superheat and subcooling values shown as XXX (not yet calculated).

  • HVACWork status not resolved

    Photograph shows a rooftop packaged HVAC unit with an access panel open, exposing an air filter and internal components including wiring; a power drill rests on top of the unit.

  • HVACWork status not resolved

    Photograph shows a Fieldpiece ST4 dual-input thermometer displaying approximately 77°F resting on an outdoor condenser unit, with copper refrigerant lines and manifold gauge hoses (blue and red) visible, indicating active HVAC diagnostic temperature testing.

Record 5Public property record

HVAC Service Invoice — No-charge service visit, no items listed

  • HVAC

On June 10, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Available findings

  • HVACCompleted work

    Service call performed on June 10, 2026 with no service lines itemized and no charge.

  • HVACWork status not resolved

    Photograph shows the interior of an outdoor HVAC condenser unit with a large fan motor fitted with a blue plastic shroud, black fan blade, purple-wired electrical component mounted to the motor housing, and aluminum fin condenser coil visible along the side panel.

  • HVACWork status not resolved

    Photograph shows the top of an outdoor HVAC condenser unit with a chrome wire fan guard, large black fan blade, and light gray painted metal cabinet, all appearing clean and free of visible debris or damage.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit interior with a large clump of compacted dust and debris on the base pan, heavily soiled fan shroud/motor housing, dirty condenser coil fins, and multiple electrical wires routed through the unit.

  • UnclassifiedWork status not resolved

    Photograph shows a gray carpet surface with a visible vertical tear or snag, with frayed and pulled fibers along the damaged line.

Record 6Public property record

HVAC Diagnostic Service — A/C diagnostic, dual-run capacitor supplied

  • HVAC

On July 1, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$385

    Performed a diagnostic on the air conditioner, with 1.5 hours of commercial maintenance labor, and supplied a dual-run capacitor.

Record 7Public property record

HVAC Diagnostic Service — Commercial diagnostic + 2.5 hrs labor

  • HVAC

On July 22, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3828 South Lindbergh Boulevard, St. Louis, MO 63127.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$434

    Performed a commercial diagnostic and 2.5 hours of commercial maintenance-rate labor at the service address.

  • HVACWork status not resolved

    Photograph shows a gray packaged rooftop HVAC unit marked '103' mounted on a metal curb on a flat commercial roof, with a white PVC condensate drain line running across the roof surface and a power drill resting on the curb, suggesting recent or ongoing installation or service work.

  • HVACWork status not resolved

    Photograph shows a large flexible insulated HVAC duct suspended by a black strap from wood ceiling joists in an open ceiling cavity, with pink fiberglass batt insulation visible between joists above.

  • HVACWork status not resolved

    Photograph shows flexible HVAC ductwork in an attic space with a severe kink and apparent damage or deterioration to the outer foil insulation jacket, with pink fiberglass batt insulation and wood framing visible overhead.

  • HVACWork status not resolved

    Photograph shows a UEI EM152 digital manometer displaying a static pressure reading of -1.05 inH2O, with probe tubes connected, resting on a gray metal HVAC unit surface.

  • HVACWork status not resolved

    Photograph shows flexible insulated HVAC ductwork running through an attic or crawl space, with a duct junction on the right side appearing loose or disconnected; pink fiberglass batt insulation is visible on the ceiling deck above.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R454B refrigerant readings: superheat (SH) 15.9°F, subcooling (SC) 7.9°F, low-side pressure 108.5 psi, and high-side pressure 251.6 psi.

  • HVACWork status not resolved

    Photograph shows a recessed light fixture housing (can light) mounted in the attic floor/ceiling deck with a flexible metal conduit attached, pink fiberglass batt insulation along the rafters, a diagonal wooden structural member, and a large dark-wrapped component resting on the deck surface.

  • HVACWork status not resolved

    Photograph shows attic interior with 8-inch R-42 insulated flexible ductwork routed through the space, alongside pink fiberglass batt insulation on the roof deck and loose-fill insulation on the attic floor.

  • HVACWork status not resolved

    Photograph shows large insulated flexible ductwork routed through an attic space alongside metallic armored conduit, with pink fiberglass batt insulation visible and debris on the attic floor decking.

  • HVACWork status not resolved

    Photograph shows a flexible black duct connected to the recessed light housing area within the ceiling plenum, routed upward toward the structural framing above.

  • HVACWork status not resolved

    Photograph shows insulated refrigerant/suction lines inside an HVAC cabinet with surface discoloration, and foil tape on the duct or cabinet edge that is visibly cracked, peeling, and deteriorating with green discoloration beneath.

  • HVACWork status not resolved

View 3828 South Lindbergh Boulevard, St. Louis, MO 63127 on Fresh House