Hi, I'm 3860 Arsenal Street. I only speak from this property's source-backed records — 7 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
3860 Arsenal Street
Across 7 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 7 documented records
Fresh House Property Summary
Highlights selected from 7 documented records for this property.
- HVAC · Two AC condensing units and coils replaced · Aug 2025$12k
- HVAC · Gas piping repaired after leak; gas shut off during service · Aug 2026
- HVAC · Indoor fan hardwired on after control board fault caused AC lines to freeze · Jun 2026
- HVAC · Old R22 system found frozen; recharge not viable, replacement recommended · Aug 2025
- HVAC · Full HVAC replacement with furnace estimated but not confirmed complete · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 3860 Arsenal Street, St. Louis, MO 63116, dated from June 2025 through August 2026. The amount summary includes $12,801.01 in completed work across HVAC, $11,844.69 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Condensing unit inspected, 2.5 lb R422b added
- HVAC
Built from Housecall Pro data
- $527HVACNormal hours service call to inspect the condensing unit, and 2.5 pounds of R422b refrigerant (Nu-22b) added.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Pinched flex duct reducing bathroom airflow
- HVAC
Built from Housecall Pro data
- HVACNormal hours service call for a tenant complaint of the system not reaching set temperature; refrigerant pressures checked fine, supply air was cold with good force, and the bathroom vent's flex duct was found pinched in many spots reducing airflow.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Frozen coil on old R22 system
- HVAC
Built from Housecall Pro data
- HVACNormal hours service call: found indoor coil and outdoor service ports completely frozen on an old R22 system that cannot be recharged without repairing the leak; leak detection, repair and recharge would exceed 50% of replacement cost.
- HVACPhotograph shows a close-up of what appears to be a frozen or heavily frosted evaporator coil inside an HVAC air handler, surrounded by spray foam insulation on metal housing panels; a hand tool is inserted into the tight space, and rust/oxidation staining is visible on the adjacent metal panel.
- HVACPhotograph shows an outdoor water meter pit with a black rubberized frame/housing, brass fittings and valves, a white PVC pipe with hex cap, and a small flexible conduit; the surrounding area contains dirt, debris, and overgrown weeds.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Equipment Installation — Two 3-ton 13.4 SEER2 R454B condensers
- HVAC
Built from Housecall Pro data
- $11,540HVACWork performed: 3 Ton 13.4 SEER2 R454B W/TXV Coil, quantity 2 (We propose to install the following equipment in your home); Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing); Equipment Warranty; Payment Terms; Terms and Conditions; Legal and Collections; 1.5% Charge On Past Due Balances (Through 9/18/2025).
- HVACPhotograph shows two side-by-side central air conditioning condenser units mounted on concrete pads against a brick exterior wall; both units have wire cage guards and top-mounted fan assemblies, and the condenser coil fins on both units appear heavily soiled with dirt and debris; refrigerant and electrical lines run up the wall to individual disconnect boxes.
- HVACPhotograph shows a gray furnace unit in the lower section and a gray air handler/coil unit in the upper section of a wood-framed utility closet, with silver foil-taped duct connections at the top, a yellow flexible gas line, white PVC condensate drain piping, and a black refrigerant line set visible.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Bad control board cool tab; fan hardwired on
- HVAC
Built from Housecall Pro data
- $219HVACNormal hours service call for AC lines freezing up; found indoor unit fan not coming on, diagnosed a bad cool tab on the control board, and hardwired the fan to stay on so the AC can cycle on and off.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement Estimate — 3-ton A/C + 95% AFUE furnace install
- HVAC
Option: Option #1 $11,844.69 (declined)
Built from Housecall Pro data
- $11,845HVACEstimate for Option #1: 3 Ton 13 Seer, 95% AFUE 70,000 BTU, TXV Cased Coil (We Propose to install the following equipment in your home), Terms and Conditions, Payment Terms, Description Full 90% Install (This proposal will include the following: New pad for condensing unit, fused), Equipment Warranty.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Gas Leak Repair — Gas leak shut off, gas piping repaired
- HVAC
Built from Housecall Pro data
- $516HVACGas leak service call with gas shut off; labor performed and black iron pipe fittings (elbows, caps, additional 5 ft exposed pipe) and a flexible gas connector supplied for gas piping repairs.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.