Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Outdoor AC condenser and coil replaced with new system · Jul 2025$5.3k
- HVAC · Old 2003 R22 condenser had faulty compressor wires and failed · Jul 2025
- HVAC · Loose furnace control board wire repaired, AC system restored · Apr 2026
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 3935 POTOMAC, St. Louis, MO 63116, dated from April 2020 through April 2026. The amount summary includes $5,454 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Compressor unrepairable; replace R22 condenser
- HVAC
Built from Housecall Pro data
- HVACService call found the outdoor condensing unit without power and the breaker tripped; the compressor wires were faulty, leaving the compressor unrepairable, and replacement of the 2003 R22 condenser and coil was recommended.
- HVACPhotograph shows an HVAC compressor with its terminal box open, revealing severely burned and charred electrical terminals consistent with an electrical failure or burnout event; the terminal block and surrounding insulation are heavily blackened, and the terminal box cover is rusted open.
- HVACPhotograph shows an outdoor AC condenser compressor with severe burn and char damage at the terminal block/electrical connection point, with visible scorching and melted material around the compressor base terminals.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condenser and Coil Installation — 2.5-ton R454B condenser
- HVAC
Built from Housecall Pro data
- $5,300HVACWork performed: 13 Seer Coil/Condenser 2.5 Ton R454B System (We propose to install the following equipment in your home: -Sure Comfort by); Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing); Install Desc - Payment Terms; Install Desc - Equipment Warranty (Equipment Warranty); Install Desc - Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service Call — Loose control board wire repaired
- HVAC
Built from Housecall Pro data
- $154HVACService call found blower coming on but no call for cool at the AC; a loose wire on the furnace control board was repaired and the system is running as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
AM Permit AM-2020-174870
On April 8, 2020, City of St. Louis documented HVAC at 3935 POTOMAC, St. Louis, MO 63116.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.