Property records for 3943 Greer Avenue, St. Louis, MO 63107

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Sewer
  • Windows

On August 26, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 3943 Greer Avenue, St. Louis, MO 63107.

Record date

Available findings

  • ElectricalWork status not resolved

    Unit 2 (first-floor) has no smoke detectors installed and requires them throughout Unit 2 bathroom light fixture and GFCI outlet are non-functional following a reported popping sound, with all panel breakers confirmed on

  • FoundationWork status not resolved

    Stone basement foundation shows common spalling with no moisture intrusion observed; inspector recommends scraping affected sections and applying Drylok or similar product to prevent future moisture intrusion.

  • Home InspectionWork status not resolved

    Whole-home inspection of a 2-family property identified multiple deficiencies including aged HVAC systems, a missing chimney cap, dry-rotted deck planks, window gaps, missing smoke detectors in Unit 2, and a non-functional bathroom electrical fixture and GFCI outlet; roof and water heaters are in satisfactory condition.

  • HVACWork status not resolved

    annual cleaning and servicing recommended no exhaust ventilation is present above gas ranges in either kitchen unit

  • PlumbingWork status not resolved

    both water heaters are performing properly

  • RoofWork status not resolved

    Architectural shingles are satisfactory and estimated 5–7 years old; masonry chimney on the north side is missing its cap and requires replacement; metal gutters present.

  • WindowsWork status not resolved

    Caulking needed around doors and windows throughout; the dining room window in the first-floor unit has a large gap that the occupant has filled with rags to block outside air.

  • SewerWork status not resolved

    Sewer lateral lines are open and flowing with no damages or obstructions observed; lines are constructed of PVC from the main stack through to the city sewer tie-in.

  • PestWork status not resolved

    no action or treatment recommended