Complete public upload archive

Property records for 4016 Botanical Avenue, St. Louis, MO 63110

All 3 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 3.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Maintenance Invoice — A/C inspection and coil cleaning

  • HVAC

On June 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4016 Botanical Avenue, St. Louis, MO 63110.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$145

    Performed air conditioning inspection and cleaning: checked air conditioner operation, cleaned coils, and checked refrigerant charge, contactor, capacitor and motor outputs.

  • HVACWork status not resolved

    Photograph shows a pleated HVAC air filter with '6/10/26' handwritten on the cardboard frame, appearing relatively clean; a tool bag and equipment are visible in the background.

  • HVACWork status not resolved

    unit sits on a concrete pad with a wire cage guard and vegetation growing at the base

  • HVACWork status not resolved
Record 2Public property record

HVAC Refrigerant Service — R-22 refrigerant, 1.5 units

  • HVAC

On June 12, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4016 Botanical Avenue, St. Louis, MO 63110.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$188

    Supplied 1.5 units of R-22 refrigerant.

Record 3Public property record

HVAC Service Invoice — No-charge service visit, no lines listed

  • HVAC

On June 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4016 Botanical Avenue, St. Louis, MO 63110.

Record date

Available findings

  • HVACCompleted work
  • HVACWork status not resolved

    Photograph shows an evaporator coil unit (Model FC37A3XN1H, Serial W1K0268883) with heavy rust and corrosion visible on the coil fins, copper tubing U-bends, and unit casing

  • HVACWork status not resolved

    Photograph shows the data plate of an outdoor HVAC condensing unit, Model No. TCGD24S41S3A, rated 208–230V/1PH/60Hz, with handwritten total refrigerant charge of 4 lbs 0 oz R-410A recorded in the charge fields.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R-410A refrigerant readings of 39.7°F / 117.0 psi (low side) and 88.5°F / 265.3 psi (high side), held in front of an outdoor AC condenser unit.

  • HVACWork status not resolved

View 4016 Botanical Avenue, St. Louis, MO 63110 on Fresh House