- HVAC · AC dual capacitor replaced at the outdoor unit · Sep 2026
- HVAC · Breaker-tripping issue on HVAC circuits was not confirmed resolved · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 405 Caithness Road, St. Louis, MO 63137. The amount summary includes $500 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Invoice — No-charge service visit, no items listed
- HVAC
Built from Housecall Pro data
- HVACInspect the electrical panel and dedicated HVAC circuits to determine why breakers are overloading/tripping; repair the circuit issue within the $500 NTE or provide a quote if it exceeds the limit.
- HVACProperty coordinator requested cancellation of HVAC work order #657995 at 405 Caithness Rd, St Louis, MO 63137, stating the visit is no longer needed
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Capacitor Replacement — Dual capacitor replaced
- HVAC
Built from Housecall Pro data
- $500HVACReplaced dual capacitor, with trip fee and apprentice labor.
- HVACPhotograph shows an outdoor HVAC condenser unit with the top panel and fan assembly removed, exposing the interior coil fins, compressor, and copper refrigerant lines; debris accumulation is visible at the base of the unit around the compressor.
- HVACPhotograph shows a Titan HD dual motor run capacitor (model PRCFD405A, 40+5 MFD, 440/370 VAC) installed inside an HVAC condenser unit's electrical compartment, with multiple colored wires connected to its terminals and two orange wire nuts visible.
- HVACPhotograph shows a mobile app screen displaying live R-410A refrigerant side readings: suction pressure 144.7 psig, suction temp 67.2°F, vapor saturation 50.7°F, actual superheat 16.5°F; liquid pressure 370.9 psig, liquid temp 95.5°F, liquid saturation 110.9°F, actual subcooling 15.4°F, discharge pressure 370.9 psig.
- HVACPhotograph shows a refrigerant diagnostic app screen displaying R-410A readings: suction pressure 144.7 psig, suction temperature 67.2°F, vapor saturation 50.7°F, actual superheat 16.5°F; liquid pressure 370.9 psig, liquid temperature 95.5°F, liquid saturation 110.9°F, actual subcooling 15.4°F, discharge pressure 370.9 psig.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.