Complete public upload archive

Property records for 41 Windcastle Place, St. Charles, MO 63304

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Maintenance — Condenser fan motor and capacitor

  • HVAC

On June 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 41 Windcastle Place, St. Charles, MO 63304.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$519

    Condenser fan motor and capacitor service performed.

Record 2Public property record

HVAC Pool Heat Pump — Pentair 120,000 Btu pool heat pump

  • HVAC

On June 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 41 Windcastle Place, St. Charles, MO 63304.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$9,400

    Supplied one Pentair pool heat pump, 120,000 Btu heat.

  • HVACWork status not resolved

    Photograph shows a Pentair UltraTemp 120H/C heat pump pool heater data plate indicating 125,000 BTU/Hr capacity, R410A refrigerant, 42.0A min circuit ampacity, and serial number 1002654795.

  • HVACWork status not resolved

    Photograph shows an outdoor pool mechanical pad with a white heat pump/heater unit, a sand or cartridge filter tank, a pool pump with blue lid, an extensive white PVC pipe manifold with multiple blue ball valves, a control/automation module, and red and black electrical wiring running along the ground.

  • HVACWork status not resolved

    Photograph shows a beige pool/spa heat pump unit installed against a brick exterior wall, sitting on a gravel bed, with multiple white PVC pipes forming the water loop at the base and sides, blue ball valves on the supply/return lines, and an electrical disconnect box mounted on the wall to the right.

  • HVACWork status not resolved

    the neutral bus bar shows corrosion and multiple wire terminations multi-colored wiring is visible at the bottom of the enclosure

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC cabinet or furnace enclosure with heavily corroded and rusted metal surfaces, deteriorated interior liner or insulation material, and significant soiling throughout the interior compartment.

  • HVACWork status not resolved

    Photograph shows a cracked black rubber/plastic pipe boot at a pipe junction, with heavy rust and corrosion on the metal pipe above and visible white mineral scaling on the fitting surface.

  • HVACWork status not resolved

    Photograph shows an electrical panel with severe fire and burn damage to at least one central breaker position — the breaker housing is visibly charred and melted, with scorching on adjacent components and the bus bar area