HVAC Repair Invoice — Breaker tripped; fan motor rewired
- Electrical
- HVAC
- Plumbing
Arch Air Services documented Electrical, HVAC, and Plumbing at 4111 Esseldale Drive, St. Ann, MO 63074.
Available findings
- HVACCompleted work$278
Diagnosed tripped breaker and condenser fan motor spinning backwards due to improper wiring; rewired fan motor (AC Rewire Level 1), tested capacitor (running weak but still operational at 35/5); noted jumped power disconnect outside as a code violation and recommended replacement with a non-fused disconnect; technician recommends upgrading the system in the near future due to overall poor condition.
- PlumbingWork status not resolved
Photograph shows a flexible corrugated hose or pipe emerging near the base of an exterior brick wall, curving along the ground, consistent with a sump pump discharge or drainage line.
- HVACWork status not resolved
Photograph shows a furnace with a large metal flue/vent pipe routed vertically upward, located in a utility closet; sticker labels are visible on the unit but not legible at this resolution.
- PlumbingWork status not resolved
Photograph shows a white water heater tank with a yellow EnergyGuide label installed adjacent to the furnace, with visible supply and connection piping at the base.
- HVACWork status not resolved
Photograph shows a furnace/air handler unit with flexible silver exhaust ductwork installed in a tight utility closet.
- PlumbingWork status not resolved
Photograph shows a tall water heater with yellow warning labels installed adjacent to the furnace in the same utility closet.
- PlumbingWork status not resolved
Photograph shows two large parallel horizontal pipes in a utility/basement ceiling area with visible surface moisture or condensation; a pull-chain light fixture, black sheeting material, and small valves or fittings are also visible.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit surrounded by heavy weed and vegetation overgrowth, with utility connections visible on the adjacent brick wall.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit situated in an overgrown grassy area alongside a structure, with a bag or toolbox visible in the lower left foreground.
- ElectricalWork status not resolved
Photograph shows an open electrical junction/meter box recessed into an exterior brick wall with exposed, unsecured wiring visible inside and no cover plate present.
- PlumbingWork status not resolved
Photograph shows exterior metal pipes with visible corrosion/green patina running along the base of the brick wall, including what appears to be a shutoff valve or fitting.