HVAC Diagnostic Service — Residential diagnostic service and labor
- HVAC
On July 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 412 Treetop Village Court, Ballwin, MO 63021.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$219
Performed a residential diagnostic service and residential labor (non-member) at the service address.
- HVACWork status not resolved
Photograph shows a 16x25x1 pleated air filter (actual size 15.75x24.75x0.75) positioned at an HVAC unit in a mechanical room; filter media appears relatively clean with wire mesh backing visible.
- HVACWork status not resolved
Photograph shows a data label on a metal HVAC unit casing displaying model A8⊘1X⊘80B M4S, serial number 2271M20JG, and line F2.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge set connected to an outdoor HVAC condensing unit, displaying R-410A refrigerant pressures on both high and low sides (approximately 362 psi and 128 psi respectively), with SC and SH subcooling/superheat readings visible on the LCD.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: superheat (SH) 11.7°F, subcooling (SC) 3.5°F, low-side pressure 130.8 psi, and high-side pressure 355.6 psi.
- HVACWork status not resolved
unit is AHRI Certified and UL Listed as a Refrigerant Condenser
- HVACWork status not resolved