HVAC Diagnostic Service — Diagnostic plus 0.33 lb R-410A refrigerant
- HVAC
On September 4, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4167 Lindell Boulevard, St. Louis, MO 63108.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$426
Performed a commercial diagnostic service with two units of commercial labor and added 0.33 pound of R-410A refrigerant.
- HVACWork status not resolved
Photograph shows an HVAC condensing unit exterior panel with two ZX08 refrigerant charging charts (System 1 and System 2), a bilingual scroll-compressor caution label, and a partial R-4x refrigerant sticker; serial number N1F7786366 is visible on both charts.
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit with bundled refrigerant lines, multi-colored control wiring secured with zip ties and wire connectors, sheet metal housing panels, and a visible fan grille/coil assembly.
- HVACWork status not resolved
Photograph shows the data plate of a Johnson Controls forced air furnace with cooling unit, model ZXG08E2B1AA1A111A2, serial N1F7786366, rated 208/230–3–60V, factory charged with R410A refrigerant; handwritten notes on the unit casing read 'T-110', '3SGF', '16 x 20', and 'Ax 4.8'.
- HVACWork status not resolved
Photograph shows a wall-mounted HVAC thermostat displaying System Info screen with terminal statuses: G (ACTIVE), Y (ACTIVE), W (INACTIVE), Y2 (ACTIVE), W2 (INACTIVE), Y3 (DISABLED).
- HVACWork status not resolved
Photograph shows a CPS brand refrigerant scale displaying 0 lbs 6.25 oz, resting on an equipment case alongside a Yellow Jacket Plus II charging hose.
- HVACWork status not resolved
Photograph shows a wall-mounted thermostat/controller displaying System Info screen: Zone Temp 76°F, Sensor Temp S1 76°F, Sensor Temp S2 88°F, Internal Humidity RH 50%, Remote Temp not supported, DC Input 0.0V.
- HVACWork status not resolved
Photograph shows a wall-mounted thermostat touchscreen displaying a 'UNIT LOCKED!!!' alert, prompting entry of a 4-character code or contact with the facility manager to make changes.
- HVACWork status not resolved
Photograph shows an ENTOUCH smart thermostat mounted on a wall, displaying a current temperature of 74°F in COOL mode, with a cool setpoint of 69°F, heat setpoint of 65°F, outside temperature of 101°F, and 51% humidity; the zone is labeled RTU1 Sales Floor.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge displaying R410A refrigerant readings: low-side temperature 48.7°F and pressure 139.5 psig; high-side temperature 125°F and pressure 447.9 psig.