Record 1Public property record

Plumbing Condition Photo — Kitchen sink faucet running water

  • Plumbing

On August 11, 2026, Drain Clean USA, LLC documented Plumbing at 4244 Miletus Drive, Florissant, MO 63033.

Record date

Record description

Roof Vent Access to clear kitchen blockage now open and flowing.

Available findings

  • PlumbingCompleted work$250

    Cabled kitchen drain line at roof vent with 1⁄2-inch cable, 50 ft; line opened and flowing; paid in full.

  • PlumbingWork status not resolved

    Technician is snaking/cabling a drain line through the roof vent stack using a motorized drain auger machine.

  • PlumbingWork status not resolved

    Photo shows a double-basin stainless steel kitchen sink with a chrome faucet actively running water into the left basin; no defects, damage, or document text are visible.

Record 2Public property record

HVAC Tune-Up Invoice — Contactor replaced; poison ivy hazard at unit

  • HVAC

On July 27, 2026, Arch Air Services documented HVAC at 4244 Miletus Drive, Florissant, MO 63033.

Record date

Available findings

  • HVACCompleted work$139

    Replaced malfunctioning contactor that was not sending power to outdoor unit and verified operation; capacitor and refrigerant levels tested ok; unit cleaning deferred due to insufficient hose length; poison ivy surrounding outdoor unit poses a safety hazard requiring removal before next service visit.

Record 3Public property record

HVAC Contactor Repair — Poison ivy around outdoor unit

  • HVAC

On July 3, 2026, Arch Air Services documented HVAC at 4244 Miletus Drive, Florissant, MO 63033.

Record date

Available findings

  • HVACCompleted work$544

    Replaced malfunctioning contactor (up to 40 AMP) on outdoor A/C unit and verified operation; capacitor and refrigerant levels tested ok; unit cleaning deferred due to insufficient hose length; poison ivy surrounding the outdoor unit poses a safety hazard requiring removal before next service visit.

  • HVACWork status not resolved

    Outdoor condenser unit is heavily soiled with dirt/debris buildup on coils, overgrown vegetation (vines) growing through the coil guard, and exposed wiring at the electrical panel; refrigerant service hoses are connected indicating active servicing.

  • HVACWork status not resolved

    Outdoor condensing unit data plate: Model N4A336AKB300, Serial E143905842, R410A refrigerant (5.51 lbs factory charge), TXV metering, 208-230V/60Hz/1PH power supply, 14.2A RLA compressor, 1/4 HP fan motor, 30A max fuse/breaker.

Record 4Public property record

Plumbing Drain Line Replacement — collapsed laundry line replaced

  • Plumbing

On March 26, 2026, Drain Clean USA, LLC documented Plumbing at 4244 Miletus Drive, Florissant, MO 63033.

Record date

Available findings

  • PlumbingCompleted work$2,000

    Replaced collapsed cast iron laundry line and standpipe with PVC line; concrete floor restored to grade; paid in full.

Record 5Public property record

HVAC Inspection and Tune-Up — Furnace precision tune-up

  • HVAC

On November 25, 2025, Arch Air Services documented HVAC at 4244 Miletus Drive, Florissant, MO 63033.

Record date

Available findings

  • HVAC$280

    Performed HVAC inspection/evaluation and furnace precision tune-up and cleaning, including pulling and cleaning burners, cleaning blower motor, checking flame sensor, gas pressure, temperature rise, wiring connections, exhaust port, and thermostat operation — heat confirmed working at time of service.

View 4244 Miletus Drive, Florissant, MO 63033 on Fresh House