Record 1Public property recordUnit d

HVAC Capacitor Service — Over 10 Mfd capacitor supplied

  • HVAC

On October 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4278 Chateau De Ville Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$349

    Trip fee charged and an over 10 Mfd capacitor supplied.

Record 2Public property record

HVAC Service Invoice — No-charge service call

  • HVAC

On October 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4278 Chateau De Ville Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    no service lines or work details are listed

  • HVACWork status not resolved

    Photograph shows a CPS digital refrigerant scale displaying 2 lbs 0.00 oz, placed on top of an HVAC unit data plate with multilingual operating instructions visible.

  • HVACWork status not resolved

    Photograph shows the data plate of a central cooling air conditioner coil section, Model No. M3UF024SA, Serial No. EGC5231929, using R22 refrigerant, factory test pressure 220 PSI, listed for cooling only.

  • HVACWork status not resolved

    Photograph shows an aged furnace unit with heavy rust and corrosion on metal surfaces; a manufacturer's data plate on the panel indicates manifold pressure 3.5 IN. WC., max amps 9.9, 115V 60Hz single phase, designed max outlet air temperature 200°F, and an apparent manufacture year of approximately 1983.

  • HVACWork status not resolved

    Photograph shows heavily soiled condenser/evaporator coil fins with significant accumulation of dust and debris between the fin rows, indicating restricted airflow and need for coil cleaning.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R407C refrigerant readings: evaporator 34.2°F at 55.4 psi (low side) and condenser 106.3°F at 247.7 psi (high side).

  • HVACWork status not resolved

    Photograph shows the interior of a furnace blower compartment with a severely clogged, dust-laden pleated air filter installed below the blower motor assembly; multiple wiring connections and wire nuts are visible at the blower motor.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R-407C refrigerant readings: superheat (SH) 15.8°F at 83.5 psi (low side) and subcooling (SC) 19.0°F at 250.9 psi (high side).

  • HVACWork status not resolved

    Photograph shows a foundation wall area (concrete block or poured concrete with white coating) in close proximity to wood framing members, with dark staining visible on the wood at the top of the frame and dusty, soiled surfaces throughout.

  • HVACWork status not resolved

    Photograph shows the exterior grille and condenser coil fins of an outdoor HVAC unit; the aluminum fins visible through the louvered grille panels appear heavily soiled with dirt and debris accumulation.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit positioned against a brick exterior wall, with flexible metallic conduit running from a wall penetration down to the unit, a weatherproof electrical plate mounted on the brick, and a gravel pad beneath the condenser; copper refrigerant line is partially visible at the base.

  • HVACWork status not resolved

    Photograph shows an exterior weatherproof electrical outlet mounted in a brick wall with its cover flap open and a cord plugged in, running down to the gravel below.

  • HVACWork status not resolved

    Photograph shows the louvered metal grille of an outdoor HVAC condenser unit with coil fins visibly clogged with heavy dirt, dust, and debris accumulation behind the slats.

  • HVACWork status not resolved

    Photograph shows the interior electrical compartment of an outdoor AC condensing unit, with a cylindrical run capacitor mounted on a bracket, a contactor relay, and multiple colored wiring connections (red, blue, brown); an R-410A refrigerant label is partially visible at the lower left.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R407C refrigerant readings: superheat (SH) 123°F, subcooling (SC) 19.0°F, low-side pressure 83.2 PSI, and high-side pressure approximately 243 PSI.

  • HVACWork status not resolved