On September 16, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 4329 Hollow Brook Court, Florissant, MO 63034.
- Record date
Available findings
- ElectricalWork status not resolved
200-amp Murray service panel is satisfactory with breaker overcurrent protection and hard-wired interconnected smoke detectors; GFCI outlet is absent in the laundry area and must be installed.
- FoundationWork status not resolved
Three cracks in the basement wall are allowing moisture intrusion and need repair with epoxy injections; other previously repaired cracks appear functional. The concrete slab leading to the front porch has sunk approximately 2 inches and needs to be jacked back to level.
- Home InspectionWork status not resolved
Whole-home inspection of 4329 Hollow Brook Ct found the home in generally good condition with no structural issues; deficiencies noted include a sunk front porch slab (~2"), defective front doorknob and deadbolt, tree limbs contacting the structure, loose soffit panels, three moisture-allowing basement wall cracks, an aged HVAC system and water heater (both 2005), and a missing GFCI outlet in the laundry.
- HVACWork status not resolved
- PlumbingWork status not resolved
sump pump and supply/waste piping are satisfactory
- RoofWork status not resolved
Architectural shingle roof estimated 5–7 years old is in good condition; tree limbs contacting the structure should be cut back, and loose soffit panels on the south side need to be secured.
- SewerWork status not resolved
Sewer lateral is open and flowing with no obstructions and no damages observed; pipe is composed of PVC from the main stack in the basement to the city sewer tie-in.
- PestWork status not resolved
no treatment recommended