- HVAC · Refrigerant leak stop service performed on the AC system · Mar 2025
- HVAC · Dual run capacitor supplied and replaced at the outdoor unit · Jul 2026
- HVAC · Air-side diagnostics recorded low airflow across the evaporator coil · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 434 Central Place, Kirkwood, MO 63122, dated from March 2025 through February 2026. The amount summary includes $711.75 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Refrigerant leak stop
- HVAC
Built from Housecall Pro data
- $450HVACRefrigerant leak stop service performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows a gas furnace with a large sheet metal supply plenum and overhead ductwork visible to the left of the water heater, with PVC condensate drain lines running along the floor.
- HVACPhotograph shows a Lennox Elite gas furnace installed in a basement utility area, connected to galvanized sheet metal supply and return ductwork; a secondary HVAC cabinet (likely air handler or coil unit) with a yellow service sticker is visible to the right.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Capacitor Service — Dual run capacitor supplied
- HVAC
Built from Housecall Pro data
- $262HVACSupplied a dual run capacitor and a trip fee was charged for the service call.
- HVACPhotograph shows a Fluke 116 HVAC True RMS multimeter displaying a reading of 42.8 placed on top of an outdoor air conditioning condenser unit's fan grille, with a screwdriver also resting on the unit, indicating active diagnostic or capacitor testing in progress.
- HVACPhotograph shows an attic-installed dark-metal air handler unit with warning labels, white PVC condensate drain piping with an elbow fitting, visible electrical wiring, and blown-in insulation scattered across the attic decking around the unit.
- HVACPhotograph shows a flexible insulated duct connected to a rectangular sheet metal plenum or duct box in an attic space, with blown-in insulation on the attic floor and wood roof framing visible in the background.
- HVACFieldpiece app air-side and refrigerant-side measurements show return dry bulb 71.1°F, supply dry bulb 50.3°F, Delta T 20.8°F, suction pressure 115.8 psig, and liquid pressure 284.3 psig.
- HVACFieldpiece refrigerant diagnostic shows R-410A system with suction pressure 115.8 psig, superheat 14.5°F, subcooling 3.0°F, and air-side diagnostic indicating supply air dry bulb (49.8°F) is below target (52.9°F), suggesting low airflow across the evaporator coil.
- HVACPhotograph shows a galvanized sheet metal air handler or plenum box in an attic space, connected to flexible insulated ductwork on multiple sides, with loose-fill insulation scattered on the attic floor around the unit.
- HVACPhotograph shows a flat-panel HVAC air filter with green pleated media and white cardboard frame being held in an attic space; flexible silver ductwork and wood framing are visible in the background.
- HVACPhotograph shows a flexible insulated duct (reflective foil/bubble-wrap jacket) connected to a round galvanized sheet metal collar mounted on a large sheet metal plenum or air handler box, located in an attic or crawl space; loose fibrous insulation is scattered around the base of the connection joint.
- HVACPhotograph shows a sheet metal plenum or air handler cabinet in an attic space, with flexible insulated ductwork connected at the rear, blown-in insulation on the attic floor, and electrical wiring visible at lower right.