HVAC Diagnostic Service — Residential diagnostic service and labor
- HVAC
On July 23, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4353 Chateau De Ville Drive, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$229
Performed a residential diagnostic service and residential labor at the service address.
- HVACWork status not resolved
Photograph shows a large pleated HVAC air filter (MERV 13 rated) removed from its housing, with pleats visibly loaded with accumulated dust and particulate matter indicating heavy use and need for replacement.
- HVACWork status not resolved
Photograph shows a dark-colored HVAC unit (furnace or air handler) with a metal mounting bracket on the wall, a flexible corrugated conduit running along the adjacent wall, and significant dark staining and rust discoloration on the structural sill/ledge at the base of the wall beside the unit.
- HVACWork status not resolved
Photograph shows a gray furnace unit with a large round metal flue/vent pipe sealed with SureTape foil tape at the top, gas piping connections at the base, flexible metal conduit, an EnergyGuide label, and a Milwaukee 25FT tape measure extended across the top of the unit, suggesting active measurement or installation work.
- HVACWork status not resolved
Photograph shows a gas furnace with connected ductwork and flexible flue piping installed in a utility closet; 'AIR FLOW' direction is hand-written on the furnace cabinet.
- HVACWork status not resolved
a small CO2 cartridge is visible on the wooden ledge at the base of the unit
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a hand holding a 400A AC/DC True RMS digital clamp meter displaying an AC amperage reading, with electrical wiring and equipment visible in the background.
- HVACWork status not resolved
Photograph shows a white HVAC air handler unit in the upper right of the mechanical room, with sheet metal flue/exhaust ducting and a large insulated pipe/duct running diagonally through the space; an orange service warning label is visible on the unit.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge displaying R22 refrigerant readings: low-side pressure 52.9 psi with superheat 46.1°F, and high-side pressure 207.3 psi with subcooling 12.6°F.
- HVACWork status not resolved
Photograph shows a mechanical room with a galvanized sheet-metal flue duct assembly, an Aprilaire 700 whole-home humidifier mounted on the duct/air handler, a sheet-metal plenum, and a black foam-insulated pipe (likely refrigerant or condensate line) wrapped around the lower duct section with visibly cracked and deteriorated insulation.