- HVAC · Multiple HVAC systems replaced throughout the building · Jun 2025
- HVAC · Three ductless heat pumps added in laundry, break room, and front office · Jun 2025
- HVAC · One unit found empty of refrigerant with signs of tampering · Jun 2026
- HVAC · All eight indoor units inspected and found in good running condition · Oct 2026
- HVAC · Three thermostats relocated from records office to hallway · Jan 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 15 documented records for 4359 Taft Avenue, St. Louis, MO 63116, dated from June 2025 through October 2026. The amount summary includes $99,338.59 in completed work across HVAC, $779 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — All systems working properly
- HVAC
Built from Housecall Pro data
- $129HVACNormal hours service call: on arrival all systems were found working properly and were checked to verify; customer advised the top floor getting warm above 85 is normal due to lack of insulation.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no items listed
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Low voltage wires repaired
- HVAC
Built from Housecall Pro data
- $129HVACNormal hours service call to repair low voltage wires.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Relocation — Thermostat relocated
- HVAC
Built from Housecall Pro data
- $194HVACNormal hours service call with half an hour of labor to relocate the thermostat.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Attic heater inspection service call
- HVAC
Built from Housecall Pro data
- $129HVACInspected for attic heaters and performed a normal hours service call.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Service call for no heat on 2nd floor
- HVAC
Built from Housecall Pro data
- HVACNormal hours service call for no heat on the 2nd floor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Relocation — 3 thermostats moved to hallway
- HVAC
Built from Housecall Pro data
- $448HVACMoved 3 thermostats from inside the records office to the hallway, with thermostat wire supplied; maintenance will need to build a soffit or use a cord track to cover exposed thermostat wire inside the office.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Questioned vent is a cold air return
- HVAC
Built from Housecall Pro data
- $130HVACChecked where cold air was entering the office area and found the questioned vent is actually a cold air return; supply vent air in room 106 measured 75 degrees, no wall cooler than 72 degrees, and desk top beneath the return 74 degrees.
- HVACPhotograph shows an infrared thermometer reading 75.9 °F current surface temperature with a recorded maximum of 76.6 °F; the surface or component being measured is not visible in the frame.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Heat kit needs second circuit from panel
- HVAC
Built from Housecall Pro data
- $129HVACNormal hours service call; found the heat kit needs a second circuit run from the breaker panel to the air handler.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Service call with ATC-3 fuse supplied
- HVAC
Built from Housecall Pro data
- $258HVACNormal hours service call with 0.5 hour of labor; ATC-3 fuse (purple) supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Unit tampered, empty of 454b and damaged
- HVAC
Built from Housecall Pro data
- $389HVACService call on 2 down units: first unit's faulty sensor was fixed and it is running; second unit was empty of 454b refrigerant and damaged, with a putty-like substance found in the service port caps indicating tampering.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Service on roof unit
- HVAC
Built from Housecall Pro data
- HVACServiced the unit on the roof.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Equipment Inspection — 8 new indoor units, no heat exchanger
- HVAC
Built from Housecall Pro data
- $390HVACInspected building equipment and heat exchangers on 8 indoor units, which all take 20x25x1 filters with no belts; systems are all new and in good running condition with no heat exchanger rust or damage.
- HVACPhotograph shows a Rheem outdoor condenser unit (model WA13NV60AJ1NA, serial W152511943, manufactured 04/2025) mounted against a white stucco wall; the data plate indicates R454a/R454b refrigerant, 175 oz factory charge, and 50A max breaker size; the 'For Field Use' refrigerant charge tag fields (Factory Charge, Charge Added, Total Charge) are all blank.
- HVACPhotograph shows a Rheem outdoor condenser unit (Model SA13NZ60AJ1NA, Serial W182414672, manufactured 05/2024), rated 208/230V single-phase, with R410A refrigerant and a factory charge of 186 oz.
- HVACPhotograph shows a label on an HVAC control system component with model number S951T1005A21M45MAS, serial number M4424165B3, and designation 'CONTROL SYSTEM KA'; wiring is visible in the lower portion of the frame.
- HVACPhotograph shows a Rheem outdoor condensing unit (Model SA13NY60AJ1NA, Serial W452405098, manufactured 11/2024) rated 208/230V single-phase, using R454b refrigerant, with a factory charge of 176 oz; field charge-added and total charge labels are blank.
- HVACPhotograph shows the data plate and wiring diagram labels on a Rheem electric air handler (PSC Motor 208/240V, Model SHIPY6024STANNJ, Serial W452409379, Refrigerant R-454B, manufactured 11/2024) mounted inside the unit's access panel, with multiple colored electrical wires visible.
- HVACPhotograph shows a data label on an HVAC control system component reading model/part number S951T1005A21M4SNAS, serial W492447760, designated 'CONTROL SYSTEM KA', with a QR code; a blower motor or similar HVAC component is visible in the background.
- HVACPhotograph shows the data plate of a Rheem outdoor air conditioner condenser unit, model SA13NY60AJ1NA, serial W4S2408334, manufactured 11/2024, rated 208/230V, 60Hz, single phase, using R454b refrigerant, with a minimum circuit ampacity of 50A and max breaker size of 40A.
- HVACPhotograph shows a metal component labeled 'CONTROL SYSTEM' with part/serial number S951T1005A21M4SNAS and W442416600, affixed with a 2D barcode sticker, within what appears to be an HVAC unit interior.
- HVACPhotograph shows the data plate of a Rheem central air conditioner (model SH1PY6024STANNJ), rated 208/240V, single-phase, 60 Hz, 7.0A nominal current, assembled in Mexico, with an electrical caution sticker affixed below.
- HVACthe label exhibits significant corrosion and dark biological staining, and electrical wiring is visible at the bottom of the unit
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — System was off; operated normally after reset
- HVAC
Built from Housecall Pro data
- HVACOn arrival the system was found turned off; thermostat was set to a lower cool temperature and the system operated as intended, and one vent serving the conference room is a long run from the system so temperature there will be monitored.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — 7 Rheem systems + 3 LG mini splits
- HVAC
Built from Housecall Pro data
- $97,793HVACInstalled five Rheem 5-ton condensing unit, 95% AFUE furnace and coil systems, two air handler/heat kit systems, and three LG ductless heat pumps (laundry, break room, front office), including pads, disconnects, drain lines, flue, gas and electrical connections, and startup.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.