HVAC Service Call — 25 ppm carbon monoxide at unit
- HVAC
On January 3, 2024, ASSURED HEATING AND COOLING documented HVAC at 4380 Tanglebrook Drive, Florissant, MO 63033.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$135
No-heat service call: found the unit switch off, replaced a clogged filter at the system blower motor with a new one, checked and cleaned all safeties, and measured 25 ppm carbon monoxide at the unit, advising replacement soon.