Complete public upload archive

Property records for 442 Elm Crossing Court, Ballwin, MO 63021

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC System Inspection — Systems optimal; zero CO reading

  • HVAC

On April 18, 2025, ASSURED HEATING AND COOLING documented HVAC at 442 Elm Crossing Court, Ballwin, MO 63021.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Performed system inspection of heating and cooling sequence of operations, checking refrigerant pressures, supply vent temperatures and carbon monoxide, and cleaning the outdoor unit; all systems functioning at optimal numbers with zero carbon monoxide reading.

  • HVACWork status not resolved

    Photograph shows the interior compartment of an HVAC air handler/furnace with the access panel removed, revealing a control circuit board mounted on a bracket with numerous multi-colored wires in a disorganized arrangement; a sticker on the board reads 'DO NOT USE FOR HEATING' and a yellow warning label at the base reads 'THIS COMPARTMENT MUST BE CLOSED EXCEPT WHEN SERVICING.'

  • HVACWork status not resolved

    Photograph shows a gray gas furnace with ENERGY GUIDE label, PVC condensate piping, and metal flue duct installed in an unfinished basement

  • HVACWork status not resolved

    Photograph shows HVAC diagnostic app screen for R-410A system (TXV) reporting System Status: Correct Charge, with current subcooling at 7° against a recommended subcooling of 10°.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the burner assembly actively firing, displaying blue flames across multiple burner ports; a gas valve (VR8205S2395) and multi-color wiring harness are visible above the burners, and an EnergyGuide label and safety warning stickers are affixed to the unit exterior.

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC unit with heavy rust and corrosion on metal panels, significant dust and debris accumulation, exposed wiring with connectors (red and green wires), and a partially visible caution label on the equipment housing.

  • HVACWork status not resolved

View 442 Elm Crossing Court, Ballwin, MO 63021 on Fresh House