Hi, I'm 4448 MINNESOTA. I only speak from this property's source-backed records — 17 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
4448 MINNESOTA
Across 17 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Permitted value
Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 17 documented records
Fresh House Property Summary
Highlights selected from 17 documented records for this property.
- Electrical · Two 100-amp panels replaced with two new 200-amp panels · Mar 2021
- HVAC · Locking security cages installed on three outdoor condensing units · Apr 2021
- Plumbing · Two electric water heaters installed in the main house · Jan 2021
- Plumbing · Gas water heater installed in garage apartment · Apr 2021
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 17 documented records for 4448 MINNESOTA, St. Louis, MO 63111, dated from January 2021 through August 2024. The amount summary includes $38,575.94 in completed work across HVAC, Electrical, and Plumbing; appraisal values and permit-declared valuations are excluded.
HVAC System Installation — 2.5-ton condenser + air handler install
- HVAC
Built from Housecall Pro data
- $6,241HVACInstalled a full system on the 2nd floor: indoor air handler, 15KW heat kit, and 13 Seer 2.5 ton condensing unit, including pad, whip, fused disconnect, drop box, filter rack and sheet metal connection to existing ductwork.
- HVACPhotograph shows an outdoor condenser unit installed on a concrete pad in a brick wall corner, with insulated refrigerant line set, an electrical disconnect box mounted on the wall, and an EnergyGuide label affixed to the unit.
- HVACPhotograph shows an outdoor split-system air conditioning condenser unit installed on a concrete pad against a brick exterior wall, with electrical disconnect boxes mounted on the wall above and refrigerant/electrical lines running to the unit.
- HVACPhotograph shows a newly positioned air handler unit connected to overhead sheet metal ductwork in a basement utility space, with the original shipping carton labeled 'AIR HANDLER' visible in the foreground and a worker in PPE present in the background.
- HVACPhotograph shows a vertical furnace or air handler unit installed in a basement/crawl space, connected to sheet metal ductwork above, with an installation instructions sheet affixed to the unit and associated electrical wiring and condensate or refrigerant lines visible.
Documented warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- Labor
· source
“We do offer a 5 year Labor warranty for an additional $500”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
- labor
· source
“We offer a one year labor warranty at no additional cost.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Electrical Wiring Installation — New circuits and breakers for HVAC
- Electrical
Built from Housecall Pro data
- $1,436ElectricalInstalled new high voltage supply wiring for both outdoor units, both heat kits and water heaters, including new circuits, breakers, and fused disconnects.
- ElectricalPhotograph shows two open electrical sub-panels mounted side by side on a plywood wall, labeled '1ST FLR' and '2ND FLR', with covers removed exposing breakers, bus bars, and multiple wiring runs; yellow AFCI/GFCI breakers are visible in both panels, and two GFCI duplex outlets are mounted below the panels; overhead wiring is disorganized.
- ElectricalPhotograph shows an open Square D electrical panel with a 100-amp main breaker labeled 'MAIN PRINCIPAL' secured with yellow lockout clips, multiple branch circuit breakers of varying amperage (15A, 20A, 40A, 50A), handwritten 'FLR' notation on the panel interior, disorganized wiring at the top, and broken knockouts at the bottom.
- ElectricalPhotograph shows two side-by-side electrical panels labeled '1st' and '2d', each with a blue MAIN PRINCIPAL breaker, multiple circuit breakers, and handwritten circuit directories listing A/C, water heater, heat, and kitchen circuits; numerous wiring runs are visible overhead.
Electrical
Electrical
ElectricalOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Full System Install — Full HVAC system install, 2-ton condenser
- HVAC
Built from Housecall Pro data
- $6,060HVACFull system install on the 1st floor: indoor air handler, 10 KW heat kit and 13 SEER 2 ton condensing unit, with pad, whip, fused disconnect, drop box, filter rack and sheet metal connected to existing ductwork.
- HVACPhotograph shows sheet metal supply trunk ductwork, transitions, and what appears to be an air handler or furnace cabinet installed in an unfinished basement with stone walls and concrete floor; a cardboard box is visible in the background.
- HVACPhotograph shows a gray gas furnace installed in a basement or crawl space, connected to sheet metal supply plenum and round flue/exhaust pipes, with a condensate drain hose at the base; surrounding foundation walls show discoloration.
- HVACPhotograph shows a wall-mounted digital thermostat displaying a current indoor temperature of 47°F with a set point of 65°F, in what appears to be a vacant interior space.
Documented warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- labor
· source
“We do offer a 5 year Labor warranty for an additional $500”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
- labor
· source
“We offer a one year labor warranty at no additional cost.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Water Heater Installation — Two electric water heaters
- Plumbing
Built from Housecall Pro data
- $2,700PlumbingInstalled two electric water heaters in the main house, each with an expansion tank and 3/4 ball valves on hot and cold sides, with copper lines up from each heater for customer to attach pex.
PlumbingOnly original contributor can modify this entry
Create an account to manage your contributions over time
Electrical Panel Upgrade — Two 100-amp panels upgraded to 200-amp
- Electrical
Built from Housecall Pro data
- $4,200ElectricalRemoved two existing 100 amp panels and upgraded to 200 amp panels, including both panels, entry cables and meter cans, with permits and planning included.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Full System Install — 80% AFUE furnace + 2-ton 13 SEER condenser
- HVAC
Built from Housecall Pro data
- $6,016HVACInstalled a full system in the garage/apartment: 80% AFUE 50,000 BTU gas furnace and 13 SEER 2 ton condensing unit, with pad, whip, fused disconnect, drop box, filter rack, sheet metal connections to existing ductwork and wiring.
Documented warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- Labor
· source
“We do offer a 5 year Labor warranty for an additional $500”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
- labor
· source
“We offer a one year labor warranty at no additional cost.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Electrical Wiring Installation — Washer/dryer outlets, grounds
- Electrical
Built from Housecall Pro data
- $1,590ElectricalInstalled washer/dryer outlets for 1st and 2nd floors, two new water grounds, and a new fan box in the second floor front room, running conduit from the main panels for the range, dryers and water run.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Water Heater Installation — 40-gallon gas water heater
- Plumbing
Built from Housecall Pro data
- $1,250PlumbingInstalled a State natural gas 40 gallon water heater with expansion tank and new shut offs, piped to accept new water lines.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condensing Unit Cages — 3 locking condensing unit cages installed
- HVAC
Built from Housecall Pro data
- $2,550HVACInstalled and mounted locking safety cages on three condensing units up to 3 ton, secured to concrete; cages act as a theft deterrent with no guarantee against removal or destruction.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Vent Installation — Vent installed
- HVAC
Built from Housecall Pro data
- HVACInstalled a vent.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no line items
- HVAC
Built from Housecall Pro data
- HVACHeating and cooling service visit on the service date with no service lines itemized.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Water Heater Repair — Water heater elements and thermostat
- Plumbing
Built from Housecall Pro data
- $119PlumbingReplaced upper and lower water heater elements and the thermostat on the upper element, with labor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 2-ton air handler + 7.5KW heat kit
- HVAC
Built from Housecall Pro data
- $4,110HVACInstalled a Sure Comfort by Rheem 2 ton air handler with 7.5KW heat kit, including new support box with filter rack and sheet metal work to supply lines and return air trunk.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Installation — 40/50 gallon water heater installed
- Plumbing
Built from Housecall Pro data
- $1,650PlumbingInstalled a 40/50 gallon gas/electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and code requirements.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condensate Pump Service — Condensate pump installed
- HVAC
Built from Housecall Pro data
- $654HVACInstalled a condensate pump and ran a new drain, cleaned all three units, and performed HVAC maintenance on three systems.
Only original contributor can modify this entry
Create an account to manage your contributions over time
AE Permit AE-2021-191319
On March 10, 2021, City of St. Louis documented Electrical at 4448 MINNESOTA, St. Louis, MO 63111.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,