Property records for 4528 Southridge Pines Drive, St. Louis, MO 63128

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Radon
  • Roof
  • Sewer
  • Windows

On September 24, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 4528 Southridge Pines Drive, St. Louis, MO 63128.

Record date

Available findings

  • Home InspectionWork status not resolved

    Whole-home inspection of single-family residence found the home in generally good condition with no structural issues, but identified multiple deficiencies including inoperable smoke detectors, a 1995 water heater near end of life, older termite damage, a PVC lateral line indentation, damaged deck banding board, missing laundry GFCI, master bath faucet leak, broken kitchen window seal, damaged basement drop ceiling framing, and a fireplace flue stuck open.

  • ElectricalWork status not resolved

    Smoke detectors throughout the home are inoperable and must be replaced laundry room lacks GFCI protection and requires a GFCI outlet installation

  • HVACWork status not resolved

    gas fireplace operates properly but the flue is stuck open and will not close, requiring repair

  • PlumbingWork status not resolved

    master bathroom vanity sink has a minor faucet leak requiring repair

  • SewerWork status not resolved

    Indentation observed in the top of the PVC lateral line approximately 5 feet from the city sewer tie-in requiring repair; main sewer stack cap has been glued shut and needs to be opened with solvent.

  • RoofWork status not resolved

    Architectural shingle roof estimated to be 5–7 years old is installed correctly and in satisfactory condition; gutters, flashings, soffit, fascia, and ventilation all satisfactory.

  • FoundationWork status not resolved

    Poured concrete foundation is in satisfactory condition with common cracks noted; inspector recommends sealing cracks with urethane caulk; no moisture intrusion was observed in the basement.

  • PestWork status not resolved

    Older termite damage is visible on the rear deck and landscaping timber with no other signs of active infestation found throughout the structure

  • WindowsWork status not resolved

    The window over the kitchen sink appears to have a broken seal and needs repair or replacement; blinds are wrong fit and need replacement; damage inside the window sill also requires repair.

  • RadonWork status not resolved

    Radon test result is ≥ EPA Action Level with an EPA protocol average of 17.6 pCi/L (overall average 17.3 pCi/L) measured over 44 hours in the basement; EPA recommends mitigation at 4 pCi/L or more.

  • SewerWork status not resolved

    Sewer lateral inspection found an indentation in the top of the PVC lateral line approximately 5 feet from the city sewer tie-in that needs to be repaired.

  • PestWork status not resolved

    Older termite damage observed on wood deck and landscape timbers; no live insects found; borate-based spray treatment recommended for affected areas.