- HVAC · Air conditioner and evaporator coil replaced with permit · Sep 2026
- HVAC · Fused electric disconnect installed with the new AC unit · Sep 2026
- HVAC · After-hours HVAC diagnostic service performed on site · Sep 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 4841 Marchwood Drive, St. Louis, MO 63128, dated in September 2026. The amount summary includes $5,458.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC After-Hours Diagnostic — After-hours diagnostic and labor
- HVAC
Built from Housecall Pro data
- $360HVACResidential diagnostic and labor performed outside normal business hours (7AM-3:30PM).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Work — 2.5-ton GMC A/C + evaporator coil
- HVAC
Built from Housecall Pro data
- $5,099HVACSupplied a 2.5-ton GMC evaporator coil and 2.5-ton GMC 13 SEER air conditioner, with a 30-amp fused electric disconnect, miscellaneous AC materials, apprentice and journeyman labor, and a St. Louis County permit.
- HVACPhotograph shows an exterior air conditioning condenser unit mounted on a concrete pad adjacent to a brick wall, with a disconnect box, conduit, and refrigerant lines visible; unit appears to be in installed condition with no visible physical damage to the cabinet or fan grille.
- HVACPhotograph shows a gas furnace with louvered front panel and a stacked evaporator coil/air handler unit connected by a round metal flue pipe, installed in a basement mechanical room a water heater is partially visible to the left rust staining is present around the floor drain below the furnace
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against a brick exterior wall, with a disconnect box to the left connected via flexible conduit and a second electrical box mounted to the wall on the right.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad against a brick wall, with a wall-mounted disconnect box connected via flexible metal conduit and a secondary electrical box with PVC conduit to the right.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad along the side of a brick house, with an electrical disconnect box and conduit visible on the wall; the unit appears to be in installed condition with no visible obvious damage.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit displaying R32 refrigerant readings: superheat (SH) 24.7°F, subcooling (SC) 10.3°F, low-side pressure 157.8 psi, and high-side pressure 403.3 psi.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condenser unit, displaying R32 refrigerant readings: superheat (SH) 24.7°F, subcooling (SC) 10.3°F, low-side pressure 157.8 psi, and high-side pressure 403.3 psi.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry