Record 1Public property record

HVAC Service Repair — Copper lines stolen, R22 lost

  • HVAC

On February 26, 2026, ASSURED HEATING AND COOLING documented HVAC at 5006 QUEENS, St. Louis, MO 63115.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$546

    Service call found indoor units taken apart and copper lines stolen with R22 released; rebuilt flue on both furnaces, replaced thermostat wire, reprogrammed Goodman furnace board, installed customer supplied thermostats, replaced coil doors, patched ductwork in one spot, and supplied 4 inch elbows, with AC system replacement recommended.

Record 2Public property record

HVAC Estimate — Two 2-ton uncased coils + 8 lb R-22

  • HVAC

On February 26, 2026, ASSURED HEATING AND COOLING documented HVAC at 5006 QUEENS, St. Louis, MO 63115.

Record date

Available findings

  • HVACEstimate or proposed work$7,606

    Estimate for 8 pounds of additional R-22 refrigerant and two 2-ton uncased coils, including sheet metal work to adapt the new coil to the duct work and a pressure test of the line set.

Record 3Public property record

HVAC Replacement Estimate — Two 2-ton 13.4 SEER2 condensers; declined

  • HVAC

On February 26, 2026, ASSURED HEATING AND COOLING documented HVAC at 5006 QUEENS, St. Louis, MO 63115.

Record date

Available findings

  • HVACEstimate or proposed work$11,820

    Estimate for Option #1: Terms and Conditions, Equipment Warranty, 2 Ton 13.4 SEER2 R454B W/TXV Coil, quantity 2 (We propose to install the following equipment in your home), Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing), Payment Terms, Theft deterrent cage, quantity 2 (We will install a welded theft deterrent cage, either mounted with legs in new).

Record 4Official permit record

AE Permit AE-2026-286865

  • Electrical

On August 4, 2026, City of St. Louis documented Electrical at 5006 QUEENS, St. Louis, MO 63115.

Permit number
AE-2026-286865
Source status
Issued
Record date
Declared valuation
$3,200Declared on the permit, not confirmed spending or proof of completed work.
Official source
City of St. LouisSource data last pulled Sep 30, 2026

Available findings

  • ElectricalEstimate or proposed work$3,200