- HVAC · B-vent with flashing, collar and cap supplied and installed · Oct 2025
- HVAC · Clogged pressure tubing cleared, restoring heat to main floor · Oct 2026
- HVAC · Heating maintenance, humidifier service and flame sensor cleaned · Oct 2026
- HVAC · Air conditioning maintained and refrigerant charge added · May 2026
- HVAC · Condenser fan motor and capacitor serviced during AC maintenance · Aug 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 5016 Country Club Drive, High Ridge, MO 63049, dated from August 2024 through October 2026. The amount summary includes $3,218.75 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Condenser fan motor and capacitor; 2-system plan
- HVAC
Built from Housecall Pro data
- $1,114HVACTwo-system maintenance plan provided and condenser fan motor and capacitor service performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Seasonal heating maintenance
- HVAC
Built from Housecall Pro data
- HVACSeasonal heating maintenance was performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — AC preventative maintenance and cleaning
- HVAC
Built from Housecall Pro data
- HVACPerformed cooling preventative maintenance and cleaning (AC maintenance).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Work — 6" b-vent with flashing, collar and cap
- HVAC
Built from Housecall Pro data
- $1,200HVACSupplied 6" b-vent with flashing, collar and cap.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Plan — Seasonal heating maintenance
- HVAC
Built from Housecall Pro data
- $510HVACSeasonal heating maintenance was performed under a maintenance plan.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance and Refrigerant Charge — A/C maintenance
- HVAC
Built from Housecall Pro data
- $395HVACAir conditioning maintenance performed under the HVAC Maintenance Plan, and refrigerant charge (410, 3 lbs max) added.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC condenser unit, displaying R410A refrigerant readings: superheat (SH) 27.5°F at 116.5 psi (low side) and subcooling (SC) 3.1°F at 258.3 psi (high side).
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor AC condenser unit displaying R410A refrigerant readings: superheat (SH) 13.0°F, subcooling (SC) 2.7°F, low-side pressure 123.4 psi, and high-side pressure 193.0 psi.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: superheat (SH) 12.0°F, subcooling (SC) 8.2°F, high-side pressure 268.9 psi, and a partially obscured low-side pressure reading.
- HVACPhotograph shows a True RMS AC/DC digital clamp meter displaying a reading of approximately 05.9 (AUTO range) being used near what appears to be an HVAC condenser unit.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R410A system, displaying low-side pressure of 118.5 psi with 11.0°F superheat and high-side pressure of 198.3 psi with 5.4°F subcooling.
- HVACPhotograph shows a digital clamp meter reading 35.02 μF (capacitance mode) being used near an outdoor HVAC condenser unit, consistent with testing a run or start capacitor.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance and Repair — No heat main floor; pressure tubing
- HVAC
- HVACFound and cleared clogged pressure tubing at draft motor restoring heat to main floor; replaced filter; performed humidifier maintenance; cleaned flame sensor; checked heat exchanger; adjusted basement thermostat from 55 to 64 and performed maintenance on basement system.