- HVAC · R-410A refrigerant recovered from the air conditioning system · Aug 2026
- HVAC · HVAC system received a commercial labor service visit · Aug 2026
- HVAC · A third HVAC service trip was made to the property · Sep 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 503 South Main Street, O'Fallon, MO 63366, dated from August 2026 through September 2026. The amount summary includes $735 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Commercial trip fee and labor
- HVAC
Built from Housecall Pro data
- $250HVACCommercial trip fee and commercial labor service performed at 503 South Main Street, O'Fallon, Missouri.
- HVACPhotograph shows a digital refrigerant diagnostic app displaying R-410A system readings: suction pressure 125.9 psig, suction temperature 44.2°F, vapor saturation 43.1°F, actual superheat 1.1°F; liquid pressure 361.5 psig, liquid temperature 94.8°F, liquid saturation 109.0°F, actual subcooling 14.2°F, discharge pressure 361.5 psig.
- HVACPhotograph shows a close-up of metal heat exchanger or radiator fins exhibiting visible rust spots, white chalky scale deposits, and surface corrosion across the fin surfaces.
- HVACPhotograph shows close-up of metallic heat exchanger tubes with helical weld beads or fins, exhibiting surface oxidation, white powdery residue, and general discoloration; sheet metal ductwork is visible in the upper right corner.
- HVACPhotograph shows two clamp meters measuring AC current inside an open HVAC unit
- HVACHVAC diagnostic app shows air-side Delta T of 25.2°F (return dry bulb 76.5°F, supply dry bulb 51.3°F), return RH 42.7%, supply RH 84.3%, and refrigerant-side suction pressure 125.8 psig with liquid pressure 362.4 psig.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — Journeyman labor and 410-A recovery
- HVAC
Built from Housecall Pro data
- $355HVACPerformed journeyman labor and 410-A refrigerant recovery at the service address.
- HVACPhotograph shows Fieldpiece app air-side measurements: Return dry bulb 78.4°F, Supply dry bulb 52.3°F, Delta T 26.1°F, Return RH 41.8%, Supply RH 89.9%; refrigerant side shows suction pressure 126.6 psig and liquid pressure 344.8 psig.
- HVACFieldpiece app refrigerant measurement shows R-410A system with suction pressure 128.6 psig, liquid pressure 351.3 psig, actual superheat 16.3°F, and actual subcooling 10.4°F.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Commercial trip fee service call
- HVAC
Built from Housecall Pro data
- $130HVACWork performed: Commercial Trip Fee.
- HVACPhotograph shows an Emerson programmable thermostat mounted on a white wall, displaying a room temperature of 76°F with a set point of 72°F and 'Cool On' active
HVAC