Plumbing Water Heater Installation — Rheem 40 Gal. gas water heater
Plumbing
On April 29, 2026, Drain Clean USA, LLC documented Plumbing at 505 Ridge Drive, Florissant, MO 63033.
Record date
Documented amount
$2,300
Record description
Drain Clean USA invoice 7915-26: installed a Rheem 40-gallon gas water heater with shutoff valve, expansion tank, flue pipe, permit and inspection ($2,000); pulled toilet and cabled the sewer main line, then reset the toilet with a new wax ring ($300). Paid in full.
Documented details
Outcome: Completed
Available findings
PlumbingCompleted work$2,300
Installed Rheem 40 Gal. gas water heater with shut-off valve, expansion tank, and flute pipe (passed permit inspection 4-29-26); also pulled toilet to cable main line, replaced wax ring, and reset toilet to floor.
Record 2·Public property record
Inspection
Electrical
Foundation
HVAC
Home Inspection
Plumbing
Roof
Sewer
On February 25, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 4 other topics at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
Home InspectionWork status not resolved
Whole-home inspection of single-family property identified multiple deficiencies including a gas-company-flagged range, blocked sewer lateral, excessively rusted 2002 water heater, and a hole in the roof over the garage; no structural deficiencies observed.
ElectricalWork status not resolved
GFCI outlet at rear patio is older and will not reset and needs replacement; loose outlet noted in dining room; 2-prong ungrounded outlets present throughout; Murray 200-amp service panel in garage appears functional.
RoofWork status not resolved
Architectural shingle roof estimated 10–15 years old with a hole in the roof over the attached garage requiring repair; remaining shingles are performing properly.
HVACWork status not resolved
Goodman central split system (2.5-ton A/C, forced-air furnace) manufactured in 2017 appears satisfactory; furnace could not be tested due to gas shutoff; missing drum panel cover noted; gas kitchen range (Amana) flagged by gas company for inoperable igniter.
PlumbingWork status not resolved
Kenmore gas water heater manufactured in 2002 is excessively rusted and needs replacement; copper supply pipes satisfactory; property is winterized with no water service active at time of inspection.
SewerWork status not resolved
Sewer lateral videoscope performed; buildup and debris have reduced the interior diameter to the point where the camera could not reach the city main — sewer lines need to be cabled/cleared then re-camera'd.
FoundationWork status not resolved
Slab-on-grade poured concrete foundation and wood-frame wall structure both observed in satisfactory condition with no structural deficiencies noted.
Record 3·Public property record
Plumbing Drain Cleaning — Hydro jet main line via roof vent
Plumbing
On June 12, 2026, Drain Clean USA, LLC documented Plumbing at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
PlumbingCompleted work$250
Hydro jetted main line roof vent for pre-maintenance to open line.
Record 4·Public property record
HVAC System Installation — Complete HVAC system installed
HVAC
On June 19, 2026, Arch Air Services documented HVAC at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
HVACCompleted work$7,187
Installed complete HVAC system at 505 Ridge Dr, Florissant, MO; mechanical permit included for the installation.
On May 14, 2026, Electrical & Data Service Co. documented Electrical at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
ElectricalCompleted work$3,967
Furnished and installed a new 200amp main breaker 40/80 circuit panel, all new breakers, new service cable, bonding bridge on meter grounding electrode conductor, THHN replacement wires, new water pipe ground, rated junction box for open-air splice in garage rafters, and sealed around service conductors to prevent rodent intrusion; Florissant electrical permit and inspection included.
This record documents Sewer at 505 Ridge Drive, Florissant, MO 63033.
Available findings
SewerEstimate or proposed work$9,945
Estimate for sewer lateral lining from main stack access to exterior transition (approx. 32') using 4" LED Flex Liner, including descaling/hydro-jetting, reinstatements, and yard clean out installation via outside excavation with SCH 40 PVC.
Record 7·Public property record
Sewer Camera Inspection — main lateral break/crack at 3-4 ft depth
Sewer
This record, dated June 1, 2026, documents Sewer at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
SewerWork status not resolved
Sewer hydro jetting performed at 505 Ridge Dr; main sewer lateral line found open with damage and scale blockage — repair by licensed plumbing contractor recommended and recamera following repairs; secondary sewer line showed no blockage; clean out is buried and inaccessible, recommend raising to grade.
SewerWork status not resolved
Sewer camera inspection of main sewer lateral at 505 Ridge Dr identified a break/crack in the line at approximately 3–4 ft depth with compromised structural integrity, and no yard vent identified — installation of yard vent recommended due to camera reel limitations; no cleanout access was found; repair by a qualified plumbing contractor is recommended.
Record 8·Public property record
HVAC Inspection-Evaluation — Furnace control board not responding
HVAC
On April 7, 2026, Arch Air Services documented HVAC at 505 Ridge Drive, Florissant, MO 63033.
Record date
Available findings
HVAC$155
HVAC inspection-evaluation performed on furnace and AC unit; furnace control board unresponsive, blower motor bearings worn, no air filter installed, outdoor coil dirty, capacitor tested weak, and low-voltage/high-voltage wiring found loose and unsecured; recommendations include new control board, filter rack, blower motor, dual capacitor, and precision tune-ups for both units.
Record 9·Public property record
Property record
Roof
Sewer
This record documents Roof and Sewer at 505 Ridge Drive, Florissant, MO 63033.
Available findings
Sewer
Sewer camera inspection of cast iron lateral at 6 Country Ln found root growth indicating a crack or separation in the pipe, and an obstruction preventing the camera from reaching the sewer main; repair recommended and reinspection advised after obstruction removal.
Roof$5,184
Removed old roof shingles and installed new roof shingles with removal of all associated trash; includes a 10-year warranty on shingles with material and labor costs.
Record 10·Public property record
Property record
HVAC
This record documents HVAC at 505 Ridge Drive, Florissant, MO 63033.
Available findings
HVAC$1,165
HVAC inspection and evaluation performed on furnace and AC; replaced main OEM circuit board, installed 16x25x1 air filter rack, and repaired gas line; furnace control board was unresponsive, blower bearings worn, AC capacitor tested weak, and thermostat/high voltage wiring found loose and unsecured.
Record 11·Public property record
Property record
HVAC
This record documents HVAC at 505 Ridge Drive, Florissant, MO 63033.
Available findings
HVAC$1,165
HVAC inspection and evaluation performed on furnace and AC; replaced main OEM circuit board, installed 16x25x1 air filter rack, and performed gas line repair; furnace control board was unresponsive, blower bearings worn, AC capacitor tested weak, and thermostat/high voltage wiring found loose and unsecured.
Record 12·Public property record
Property record
Sewer
This record documents Sewer at 505 Ridge Drive, Florissant, MO 63033.