  • HVAC
    HVAC · Furnace control board replaced under service work order · May 2026
  • HVAC
    HVAC · Furnace lost heat; flooding damaged the control board · May 2026
  • HVAC
    HVAC · AC condensate drain cleared after clog caused leaking · Aug 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 524 Gerald Place. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

3 documented events
Contributed by: 1 contributor
First documented event: May 2026
Latest documented event: Aug 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 3 documented records for 524 Gerald Place, Ferguson, MO 63135, dated from May 2026 through August 2026. The amount summary includes $1,135.15 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Condensate Drain Service — Clogged condensate drain cleared

Document dated Aug 24, 2026Uploaded Nov 11, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 524 Gerald Place, Ferguson, MO 63135.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $269
  • HVACResponded to a leaking AC coil at a vacant unit and found the condensate drain clogged; cleared the line and fitting with a CO2/nitrogen condensate drain purge, and it is draining as intended.
    $269

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Maintenance — Furnace needs new control board (flooding)

Document dated May 13, 2026Uploaded Nov 10, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 524 Gerald Place, Ferguson, MO 63135.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $154
  • HVACNo heat service call; technician found the furnace needs a new control board due to flooding.
    $154
  • HVACPhotograph shows the interior of a furnace/air handler with the access panel removed, revealing a control board (model 1194-250), transformer, and multiple multi-colored wiring harnesses; significant dust, dirt, and debris accumulation is visible on the interior surfaces and bottom pan, along with a coiled brown wire/cable.
  • HVACPhotograph shows a Rheem natural gas forced-air furnace data plate with model number R801T0754A17[partially obscured]AS, serial number W022322947, manufactured 01/2023, rated at 75000 BTU/hr (21.98 kW) maximum hourly input, equipped for natural gas.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Control Board Replacement — Control board replaced

Document dated May 19, 2026Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 524 Gerald Place, Ferguson, MO 63135.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $713
  • HVACReplaced control board under work order 33207-2.
    $713

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history