HVAC Diagnostic and Refrigerant Service — Diagnostic plus 410-A
- HVAC
On March 25, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5339 ITASKA, St. Louis, MO 63109.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$464
Performed a residential diagnostic service and added 410-A refrigerant (3 lb max).
- HVACWork status not resolved
Photograph shows an air handler unit (marked '2W') with heavy ice and frost accumulation on the refrigerant copper line insulation, a blue inline filter drier installed on the refrigerant line, sheet metal ductwork with foil tape, and a CAUTION label referencing refrigerant servicing.
- HVACWork status not resolved
Work order in progress for air conditioner producing no cold air; resident reports issue started the previous day during warm weather, scheduled for service on March 23 at 2:00PM.
- HVACWork status not resolved
Photograph shows a Yellow Jacket digital refrigerant scale displaying a reading of 2.05 lb, resting on a concrete surface with coiled hoses and a blue refrigerant cylinder partially visible.
- HVACWork status not resolved
Photograph shows a Testo digital refrigerant manifold gauge in Refrigeration mode displaying HP 228.9 psi, LP 75.2 psi, T1 63.0°F, T2 32.0°F, SC 44.9°F, consistent with R410A system diagnostics.
- HVACWork status not resolved
Photograph shows a handheld refrigeration manifold analyzer displaying: Low Pressure (LP) 111.7 psi / 37.0°F evaporating, High Pressure (HP) 256.3 psi / 85.2°F condensing, T1 51.4°F, T2 32.0°F, Superheat (SH) 14.4°F, Subcooling (SC) 53.2°F, refrigerant R410A.
- HVACWork status not resolved
Photograph shows the underside/base edge of a toilet with a visibly deteriorated wax ring or gasket exhibiting orange, yellow, and dark brown/black discoloration, fibrous material breakdown, and a gap between the toilet base and the floor surface.
- HVACWork status not resolved
service sticker affixed to the unit
- HVACWork status not resolved
Photograph shows an HVAC coil assembly inside a galvanized sheet metal enclosure with heavy rust and corrosion visible on surrounding components, piping, and casing, along with debris accumulation at the base of the coil.
- HVACWork status not resolved
- HVACWork status not resolved
Air conditioner maintenance meld showing two associated contacts; no work description, date, or financial details are visible.