Inspection (07/03/2026)
- Electrical
- Foundation
- HVAC
- Home Inspection
- Pest
- Plumbing
- Roof
- Sewer
On July 1, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 545 Crystal Stream Drive, Wentzville, MO 63385.
- Record date
Available findings
- PestWork status not resolved
Wood Destroying Insect inspection of SFR/Attached Garage at 545 Crystal Stream Drive found no visible evidence of wood destroying insects; no action or treatment recommended.
- Home InspectionWork status not resolved
Whole-home inspection of 545 Crystal Stream Dr identified 6 deficiencies across site, roofing, HVAC, plumbing, and electrical systems, including loose patio handrails, a damaged fence post topper, and a loose exterior faucet; home described as in great condition with no structural issues.
- RoofWork status not resolved
Architectural shingle roof inspected by drone and found satisfactory; deficiency noted: missing splashblock on the north side of the home at a downspout.
- HVACWork status not resolved
2015 Lennox central split system (71,000 BTU furnace, 3-ton condenser) is performing properly but needs cleaning and servicing; damaged foam insulation over evaporator lines requires replacement; condensation line needs a suspension clamp to prevent pooling on basement floor.
- PlumbingWork status not resolved
Water heater expansion tank valve shows signs of a minor leak and needs repaired or replaced; Rheem 50-gallon natural gas water heater manufactured 2015 with no seismic straps installed; exterior faucet on north side of home is loose and needs secured.
- ElectricalWork status not resolved
200-amp Eaton service panel (newer, appears functional) located in basement; GFCI outlet is not present in the laundry room and needs to be installed.
- FoundationWork status not resolved
Poured concrete basement foundation satisfactory with no moisture detected; informational note to seal a common floor crack next to the sump pump with urethane caulk.
- SewerWork status not resolved
Sewer lateral lines are open and flowing with no damages or obstructions observed; lines are dirty and enzyme-based drain cleaner is recommended for maintenance.