Hi, I'm 5636 South Magnolia Avenue. I only speak from this property's source-backed records — 17 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
5636 South Magnolia Avenue
Across 17 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 17 documented records
Fresh House Property Summary
Highlights selected from 17 documented records for this property.
- HVAC · Outdoor AC condensing unit replaced with new unit and coil · Aug 2024
- HVAC · Bypass humidifier installed with new water line · Nov 2021
- HVAC · Nest thermostats wired and common wires added to both systems · May 2021
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 17 documented records for 5636 South Magnolia Avenue, St. Louis, MO 63139, dated from May 2021 through June 2026. The amount summary includes $8,387.91 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Thermostat Service Call — Nest thermostats wired
- HVAC
Built from Housecall Pro data
- $149HVACNormal hours service call to inspect and wire Nest thermostats, add common wires to the Nest thermostats and test systems; advised to replace 16x25x1 filter.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Low R410A, iced unit; recharged 2.75 lbs
- HVAC
Built from Housecall Pro data
- $355HVACService call found the A/C unit extremely low on R410A with ice on the system; removed the ice, cleaned the outdoor unit, and charged the unit with 2.75 lbs of R410A, leaving all systems working as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Clean and Check — Humidifier water valve locked up
- HVAC
Built from Housecall Pro data
- $178HVACFurnace clean and check on two Carrier units: replaced filters, checked burners, flame combustion, pressure switch, vacuum lines, relays and safeties; carbon monoxide readings of 14 ppm and 11 ppm taken; humidifier has a locked up water valve and replacement was recommended if needed this winter.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Humidifier Installation — Bypass humidifier installed with new
- HVAC
Built from Housecall Pro data
- $675HVACInstalled and wired a bypass humidifier and installed a new water line; a saddle valve connection would be replaced with a code approved connection.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Service — Main floor AC unit low on charge
- HVAC
Built from Housecall Pro data
- $215HVACAC maintenance performed: cleaned outdoor units, checked system charge, replaced indoor unit filters, checked electrical components, and added refrigerant; main floor unit found low on charge and customer advised, with a return visit planned May 3rd-4th to inspect for leaks.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Leak Check — Indoor coil leak; replacement recommended
- HVAC
Built from Housecall Pro data
- HVACInspected indoor and outdoor coils and line set for system leaks; system was charged with R410A in 2021 and 2022, and two spots on the indoor coil triggered the digital leak detector, so coil replacement is recommended due to the severity of the leak.
- HVACPhotograph shows a data plate label on an HVAC evaporator coil unit, model CNPVP3017ATAABAA, serial 2008X29171, manufactured 12 May 2008, with an orange distributor return/credit label also affixed.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service call, no items listed
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Evaporator Coil Replacement — Indoor evaporator coil replaced
- HVAC
Built from Housecall Pro data
- $2,367HVACRemoved and replaced indoor evaporator coil (cased coil).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Tune-Up — Two furnace tune-ups, filters replaced
- HVAC
Built from Housecall Pro data
- HVACFurnace tune-up performed on two units and filters replaced (16x25x1, 16x20x1); lower level safeties clean, second floor heat kit amp reading 17.9 within proper range.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Membership Visit — Gold Membership Plan visit #3
- HVAC
Built from Housecall Pro data
- HVACVisit #3 completed under the Gold Membership Plan, per system, at no charge.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — General maintenance on 2 HVAC units
- HVAC
Built from Housecall Pro data
- HVACPerformed fall or spring general HVAC maintenance on 2 units.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Membership Plan Visit — Gold Membership Plan visit #5
- HVAC
Built from Housecall Pro data
- HVACVisit #5 under the Gold Membership Plan, per system, was performed at the service address.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — 2.5-ton condensing unit and coil installed
- HVAC
Built from Housecall Pro data
- $4,450HVACInstalled a 2.5 ton R410A condensing unit and coil, including fused disconnect, electrical whip, pad, sheet metal work to adapt the coil to ductwork, and chemical flush and pressure test of the line set.
- HVACPhotograph shows an outdoor condenser unit with insulated refrigerant line set (suction and liquid lines), brass service valves with caps, and a gray outdoor electrical disconnect box mounted on the house siding; exposed soil is visible around the unit base.
- HVACPhotograph shows two outdoor air conditioning condenser units mounted against residential siding; the larger left unit displays a 'Sure' brand badge, while the smaller right unit appears older with no visible branding.
- HVACGAS' installed in a utility space
- HVACFieldpiece app refrigerant side measurements for R-410A system: suction pressure 123.8 psig, liquid pressure 300.6 psig, actual superheat 12.6°F, and actual subcooling 10.0°F.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no lines itemized
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Membership Visit — Gold Membership Plan visit #6
- HVAC
Built from Housecall Pro data
- HVACVisit #6 under the Gold Membership Plan, per system.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Membership Plan Visit — Gold Membership Plan visit #9
- HVAC
Built from Housecall Pro data
- HVACVisit #9 under the Gold Membership Plan, per system, was performed at the property.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — System working as intended, no problems found
- HVAC
Built from Housecall Pro data
- HVACNormal hours service call for a reported new system not working properly; on arrival the system was working as intended with perfect pressures, and no problems were found with the Nest stat or older furnace.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,