Complete public upload archive

Property records for 5730 Briarwood Estates Drive, St. Louis, MO 63129

All 3 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 3.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Call — Trip fee and 410-A refrigerant

  • HVAC

On April 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5730 Briarwood Estates Drive, St. Louis, MO 63129.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$144

    Trip fee charged and 410-A refrigerant supplied for HVAC service call.

  • HVACWork status not resolved

    Photograph shows a manufacturer's data plate on an air conditioning condensing unit: Model 4AC13B60P-3A, Serial 1910C05182, HFC-410A refrigerant with 10 lb 0 oz factory charge, 208/230V 1PH 60Hz, compressor RLA 26.3/LRA 120.0, fan motor FLA 1.7 HP 1/4, min circuit ampacity 34.6, max fuse/breaker 60A.

  • HVACWork status not resolved

    Photograph shows an evaporator coil interior with significant rust and corrosion visible on the copper refrigerant tubing and U-bend connections, along with accumulated dirt on the aluminum fins and surrounding sheet metal cabinet.

  • HVACWork status not resolved

    Photograph shows a large exterior air conditioning condenser unit with a wire mesh guard positioned against the side of a residential building, alongside a round metal exhaust/vent pipe penetrating the siding with a square wall plate.

  • HVACWork status not resolved

    Photograph shows a Testo digital manifold gauge displaying R410A refrigerant readings: low-side pressure 104.5 psig, high-side pressure 245.7 psig, evaporator saturation temp 33.6°F, condenser saturation temp 82.5°F, T1 48.5°F, superheat 14.9°F, and subcooling not available (XXX).

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC air handler or furnace cabinet with heavy dust and debris accumulation on all metal surfaces, visible circular knockouts or ports on the back wall, and a 'MADE IN THE USA' stamp on the unit floor; deteriorated material is visible along the left opening.

  • UnclassifiedWork status not resolved

    Photograph shows a Yellow Jacket brand digital moisture meter lying on grass and clover vegetation, with the LCD display showing a reading of approximately 64; a yellow-capped bottle and dark cylindrical object are visible nearby.

  • HVACWork status not resolved

    Photograph shows an evaporator coil assembly with heavily corroded and rust-covered refrigerant U-bend tubing, dirty fin surfaces, and a soiled, deteriorated coil cabinet interior.

  • HVACWork status not resolved

    Photograph shows a gray metal electrical panel mounted in a utility space, with a large looping conduit or cable running alongside it and a metal junction box visible between the panel and the wood-framed wall.

  • HVACWork status not resolved

    Photograph shows a yellow dual-channel thermocouple thermometer with two probe connectors placed among overgrown weeds and wildflowers against a gray concrete wall, alongside yellow and multicolored hoses or cables.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a handheld electronic meter displaying a reading of 6 ppm being held near a door frame, with exposed subfloor framing visible in the background.

Record 2Public property record

HVAC Estimate Visit — No-charge HVAC estimate visit

  • HVAC

On July 18, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5730 Briarwood Estates Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

    An estimate visit was provided at the service address at no charge.

  • HVACWork status not resolved

    Photograph shows the manufacturer's data plate on an outdoor HVAC condensing unit, model 4AC13B60P-3A, serial 1910C05182, rated 208/230V single-phase, containing HFC-410A refrigerant with a 10 lb 0 oz factory charge.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant pressures of 117.3 psi (low side) and 355.3 psi (high side) with a subcooling value of 4.9°F.

  • HVACWork status not resolved
Record 3Public property record

HVAC Service Invoice — No-charge service call, no line items

  • HVAC

On July 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5730 Briarwood Estates Drive, St. Louis, MO 63129.

Record date

Available findings

  • HVACCompleted work

View 5730 Briarwood Estates Drive, St. Louis, MO 63129 on Fresh House