HVAC Service Call — Trip fee and 410-A refrigerant
- HVAC
On April 6, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 5730 Briarwood Estates Drive, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$144
Trip fee charged and 410-A refrigerant supplied for HVAC service call.
- HVACWork status not resolved
Photograph shows a manufacturer's data plate on an air conditioning condensing unit: Model 4AC13B60P-3A, Serial 1910C05182, HFC-410A refrigerant with 10 lb 0 oz factory charge, 208/230V 1PH 60Hz, compressor RLA 26.3/LRA 120.0, fan motor FLA 1.7 HP 1/4, min circuit ampacity 34.6, max fuse/breaker 60A.
- HVACWork status not resolved
Photograph shows an evaporator coil interior with significant rust and corrosion visible on the copper refrigerant tubing and U-bend connections, along with accumulated dirt on the aluminum fins and surrounding sheet metal cabinet.
- HVACWork status not resolved
Photograph shows a large exterior air conditioning condenser unit with a wire mesh guard positioned against the side of a residential building, alongside a round metal exhaust/vent pipe penetrating the siding with a square wall plate.
- HVACWork status not resolved
Photograph shows a Testo digital manifold gauge displaying R410A refrigerant readings: low-side pressure 104.5 psig, high-side pressure 245.7 psig, evaporator saturation temp 33.6°F, condenser saturation temp 82.5°F, T1 48.5°F, superheat 14.9°F, and subcooling not available (XXX).
- HVACWork status not resolved
Photograph shows the interior of an HVAC air handler or furnace cabinet with heavy dust and debris accumulation on all metal surfaces, visible circular knockouts or ports on the back wall, and a 'MADE IN THE USA' stamp on the unit floor; deteriorated material is visible along the left opening.
- UnclassifiedWork status not resolved
Photograph shows a Yellow Jacket brand digital moisture meter lying on grass and clover vegetation, with the LCD display showing a reading of approximately 64; a yellow-capped bottle and dark cylindrical object are visible nearby.
- HVACWork status not resolved
Photograph shows an evaporator coil assembly with heavily corroded and rust-covered refrigerant U-bend tubing, dirty fin surfaces, and a soiled, deteriorated coil cabinet interior.
- HVACWork status not resolved
Photograph shows a gray metal electrical panel mounted in a utility space, with a large looping conduit or cable running alongside it and a metal junction box visible between the panel and the wood-framed wall.
- HVACWork status not resolved
Photograph shows a yellow dual-channel thermocouple thermometer with two probe connectors placed among overgrown weeds and wildflowers against a gray concrete wall, alongside yellow and multicolored hoses or cables.
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a handheld electronic meter displaying a reading of 6 ppm being held near a door frame, with exposed subfloor framing visible in the background.