← MAP

6197 Lemay Ferry Road

St. Louis, MO 6312938.4654°N, 90.3576°W
3Events
Contributed by:1 contributor
$1kDocumented amounts
SOURCE-BACKED RECORDS

Across 3 records on this property

Completed work

Invoices and paid receipts

$1k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Fresh House Property Summary

Highlights selected from 3 documented records for this property.

  • HVAC
    HVAC · Commercial HVAC rooftop unit diagnosed with overtime labor · Aug 2026
  • HVAC
    HVAC · Commercial HVAC unit diagnosed and drive belt replaced · Sep 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 6197 Lemay Ferry Road. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

3 documented events
Contributed by: 1 contributor
First documented event: Sep 2026
Latest documented event: Sep 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 3 documented records for 6197 Lemay Ferry Road, St. Louis, MO 63129, dated in September 2026. The amount summary includes $1,020 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Diagnostic Service — Overtime diagnostic and 1.5 hrs labor

Document dated Aug 15, 2026Uploaded Nov 9, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6197 Lemay Ferry Road, St. Louis, MO 63129.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $725
  • HVACPerformed a commercial overtime diagnostic and 1.5 hours of overtime labor outside normal hours.
    $725
  • HVACPhotograph shows interior of an HVAC unit with a finned coil and a fan motor; multiple colored wires (blue, green/yellow, brown) run from the motor with an exposed wire splice and visibly worn/damaged insulation at the connection point.
  • HVACPhotograph shows a digital thermometer (model DFP450W, NSF-certified, range -40/450°F) clipped to a metal panel labeled 'RTU 1 / 2A', displaying a temperature reading of approximately 64.9°F.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Invoice — No-charge service visit

Document dated Aug 18, 2026Uploaded Nov 9, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6197 Lemay Ferry Road, St. Louis, MO 63129.
Scope
  • HVAC

Built from Housecall Pro data

  • HVACPhotograph shows interior of rooftop unit labeled 'Rtu 1' with two AX38-BTN drive belts (manufactured 2014, Made In P.R.C.) visible on the blower assembly; belts and surrounding components show significant dust and wear accumulation.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Diagnostic Service — Commercial diagnostic, AX38 belt supplied

Document dated Sep 29, 2026Uploaded Nov 9, 20266 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 6197 Lemay Ferry Road, St. Louis, MO 63129.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $295
  • HVACPerformed a commercial diagnostic service with commercial labor and supplied an AX38 belt.
    $295
  • HVACPhotograph shows the interior of an open HVAC air handler unit with a belt-driven blower assembly; a technician's hand holds a removed worn toothed drive belt alongside the newly installed replacement belt on the motor and blower pulleys.
  • HVACPhotograph shows the interior of an open HVAC unit revealing a large centrifugal blower wheel with belt drive, a motor, multiple wiring harnesses (red, yellow, green wires; some loosely coiled), a control board or wiring diagram on the left panel, and a small wall-mounted control device; interior sheet metal shows dust and dirt accumulation.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+1

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this property.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby properties with documented history