HVAC Diagnostic Service — Diagnostic, 410-A refrigerant
- HVAC
On June 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 6331 Sean Parkway, St. Louis, MO 63129.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$369
Performed a residential diagnostic service, supplied 2 units of 410-A refrigerant, and supplied a compressor hard-start kit.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements for R-410A system: suction pressure 142.8 psig, liquid/discharge pressure 452.2 psig, actual superheat 13.4°F, actual subcooling 4.9°F; air side diagnostics show supply dry bulb 57.7°F vs. target 57.9°F, indicating adequate airflow across the evaporator coil.
- HVACWork status not resolved
Fieldpiece app measurements show air-side Return dry bulb 75.8°F / Supply dry bulb 57.7°F with a Delta T of 18.1°F; refrigerant-side suction pressure 142.7 psig and liquid pressure 452.2 psig.
- HVACWork status not resolved
Photograph shows a Yellow Jacket brand digital manifold/vacuum gauge lying on a concrete surface with a black hose connected, displaying a reading of 200 on its LCD screen.
- HVACWork status not resolved